Inspection Reports for
Cross Creek at Lee‘s Summit

MO, 64064

Back to Facility Profile

4 Reports

2018–2023

Inspection Report — Nov 28, 2023

Routine
Date: Nov 28, 2023

Visit Reason
Missouri Department of Health and Senior Services State Form (Missouri licensure survey); the survey type is not stated.

Findings
1 Missouri State Form deficiency concerning protective oversight related to side rails and low air loss mattresses, including missing assessments, physician orders, staff training, and policy gaps.

Deficiencies (1)
19 CSR 30-86.047(35) Protective Oversight: Based on observation, interview and record review, the facility failed to ensure side rail assessments, physician orders, and staff training related to side rails and low air loss mattresses for sampled residents, and lacked policies addressing side rail and LALM use.
Report Facts
sampled residents missing side rail assessments: 4 residents missing physician orders for side rails: 2 sampled residents at increased entrapment risk with side rails and LALMs: 2

Inspection Report — Aug 24, 2022

Routine
Date: Aug 24, 2022

Visit Reason
Missouri state licensure survey (State Form); the survey type is not stated.

Findings
One state licensure deficiency was cited for failure to develop and implement a plan to safeguard a resident who required staff assistance with wheelchair mobility; cited as Class II.

Deficiencies (1)
19 CSR 30-86.047(28)(J) Plan to Safeguard Residents: Based on interview and record review, the facility failed to ensure a plan was developed to ensure the safety of one resident (Resident #1) out of three sampled residents who required staff assistance with wheelchair mobility throughout the facility.
Report Facts
residents affected: 1 residents sampled: 3

Inspection Report — Sep 12, 2019

Routine
Date: Sep 12, 2019

Visit Reason
Missouri state licensure survey (State Form); the survey type is not stated.

Findings
4 state licensure deficiencies were cited involving fire drill/evacuation plan consultation, fire drill requirements, fire alarm testing/maintenance, and sprinkler system documentation. Two deficiencies were cited as Class III and two as Class II.

Deficiencies (4)
19 CSR 30-86.022(5)(A) Fire Drill/Evacuation Plan, Consultation: Based on record review and interview the facility failed to provide documentation of a current annual local fire department consultation.
19 CSR 30-86.022(5)(D) Fire Drill Requirements, Evacuation: Based on record review and interview the facility failed to provide documentation of required fire drills being performed at least once every three months on each shift.
19 CSR 30-86.022(9)(C) Fire Alarm System-Test/Maintain: Based on record review and interview the facility failed to provide documentation of semi-annual fire alarm system inspection/testing.
19 CSR 30-86.022(11)(A) Complete Sprinkler System-NFPA 13: Based on record review and interview the facility failed to provide documentation of monthly sprinkler system checks as required, with missing readings for several months.
Report Facts
residents affected: 44

Inspection Report — Sep 26, 2018

Routine
Date: Sep 26, 2018

Visit Reason
Missouri state licensure survey (State Form); the survey type is not stated.

Findings
2 state deficiencies concerning sprinkler system maintenance/testing and electrical wiring inspection/maintenance; both deficiencies lacked required documentation and affected all residents.

Deficiencies (2)
19 CSR 30-86.022(11)(B) Sprinkler System Maintenance/Testing: The facility failed to provide documentation of monthly sprinkler system pressure checks being performed.
19 CSR 30-86.032(13) Electrical Wiring, Maintained, Inspected: The facility failed to provide documentation that facility wiring was inspected every two (2) years by a qualified electrician.
Report Facts
residents affected: 39

Viewing

Loading inspection reports...