Inspection Reports for
The Legacy of Bothell
305 240th St SW, Bothell, WA, 98021
Back to Facility Profile4 Reports
Inspection Report — Feb 18, 2026
Follow-Up
Date: Feb 18, 2026
Visit Reason
The Department completed a follow-up inspection of the Assisted Living Facility to verify correction of previously cited deficiencies.
Findings
The follow-up inspection found no deficiencies and confirmed that all previously cited deficiencies were corrected.
Deficiencies (2)
WAC 388-78A-2481 Tuberculosis Testing method Required. The assisted living facility failed to ensure 1 of 3 newly hired staff was screened for Tuberculosis within three days of being hired, placing all residents at risk.
WAC 388-78A-2665 Resident rights Notice Policy on accepting medicaid as a payment source. The assisted living facility failed to obtain resident signatures on their Medicaid policy, placing all residents at risk of not knowing their rights.
Report Facts
Sampled residents: 5
Residents at risk: 28
Inspection Report — Dec 17, 2024
Follow-Up
Date: Dec 17, 2024
Visit Reason
The Department completed a follow-up inspection of the Assisted Living Facility to verify correction of previously cited deficiencies.
Findings
The follow-up inspection found no deficiencies and confirmed that the facility meets the Assisted Living Facility licensing requirements. Previously cited deficiencies were corrected.
Deficiencies (3)
WAC 388-78A-3100 Safe storage of supplies and equipment. The assisted living facility must secure potentially hazardous supplies and equipment commensurate with the assessed needs of residents and their functional and cognitive abilities. The facility failed to secure manicure sets and housekeeping carts, placing all residents at risk.
WAC 388-78A-2462 Background checks Who is required to have. The assisted living facility must ensure that contractors who may have unsupervised access to residents have a Washington state background check. The facility failed to ensure a contracted employee had a completed background check, placing all residents at risk.
WAC 388-78A-2730 Licensee's responsibilities. The assisted living facility licensee is responsible for complying with applicable laws and rules. The facility failed to obtain a Medical Testing Site Waiver/CLIA certificate by the deadline, placing all residents at risk for receiving waived tests without proper certification.
Report Facts
Residents at risk: 30
Sample size: 5
Inspection Report — Jul 21, 2023
Follow-Up
Date: Jul 21, 2023
Visit Reason
The Department completed a follow-up inspection of the Assisted Living Facility to verify correction of previously cited deficiencies.
Findings
The follow-up inspection on 07/21/2023 found no deficiencies and confirmed that all previously cited deficiencies were corrected.
Inspection Report — Nov 3, 2022
Life Safety
Date: Nov 3, 2022
Visit Reason
The Office of the State Fire Marshal conducted a fire safety inspection at the new 15-bed memory care facility, Legacy of Bothell, Phase II, to assess compliance with fire protection and life safety codes.
Findings
The inspection found multiple fire safety violations including missing sprinkler system documentation, missing escutcheon ring on a sprinkler head, improperly mounted fire extinguishers, absence of carbon monoxide alarms in several areas, and emergency exit doors equipped with prohibited key-operated dead bolts. The facility was disapproved and required to correct all violations upon re-inspection.
Deficiencies (6)
2016 NFPA 13 6.2.9.7 - The facility failed to provide a list of the sprinklers installed within the facility to be located within the sprinkler cabinet.
No code number given - There is no hydraulic calculation nameplate located on the sprinkler system.
No code number given - One sprinkler head in the basement kitchen storage was missing the escutcheon ring.
IFC 906.7 (2015, 2018) - Fire extinguishers throughout the facility are not mounted in accordance with the manufacturer's installation instructions.
IFC 915.1.4 (2018) - There are no carbon monoxide alarms in the laundry room, workshop, upstairs kitchen, or downstairs kitchen where gas-fed appliances are used.
IFC 1010.1.9.5 (2018) - The labeled emergency exit doors on the 1st floor north side and basement south side to the courtyard have key operated dead bolts on the doors.
Report Facts
Total licensed beds: 15
Viewing
Loading inspection reports...