Inspection Reports for
Voyage Residential Care
500 BARRETT DRIVE, MALDEN, MO, 63863-1204
Back to Facility Profile3 Reports
Inspection Report — Jun 4, 2026
Routine
Date: Jun 4, 2026
Visit Reason
Missouri state licensure survey (State Form); the survey type is not stated.
Findings
1 state licensure deficiency (Class III) for unsanitary kitchen equipment and failure to maintain clean food-contact surfaces on cooking equipment, including stove, oven, griddle and deep fryer.
Deficiencies (1)
19 CSR 30-87.030(64) Grills/Griddles/Microwaves/Other-Clean Daily: Based on observation and interview, the facility failed to maintain the stove, oven, griddle and deep fryer by keeping them clean and free of debris build-up, which had the potential to affect all residents. Observations showed black crusty residue on the four-burner stove, black charred areas and crumbled foil in the oven, a greasy griddle, greasy residue inside and on the deep fryer, and a greasy puddle with pieces of food on the floor behind the stove.
Inspection Report — May 28, 2025
Routine
Date: May 28, 2025
Visit Reason
Missouri state licensure survey (State Form); the survey type is not stated.
Findings
4 state licensure deficiencies were cited. The deficiencies concern furniture/equipment repair and safety, room cleanliness and housekeeping, mattress condition, and provision of towels/handwashing supplies.
Deficiencies (4)
19 CSR 30-86.032(22) Furniture/Equip, Provide Comfort & Safety: Based on observation and interview, the facility failed to ensure resident use furniture was well maintained and kept in good repair. Observation of Resident #2's room showed a large counter with a sink and mirror, the cabinet below the counter had one door missing and the decorative panel on the cabinet was missing; the resident reported maintenance had not returned to make the repair.
19 CSR 30-86.032(23) Rooms Neat, Orderly, Cleaned Daily: Based on observation and interview, the facility failed to ensure all resident use areas and all resident rooms were kept neat, orderly and in good repair. Observations included food crumbs on the floor in room #201, a large tray of tobacco and tobacco on the floor in room #118, brown stains on the floor and ants, and a laundry room sink full of slimy, dirty water.
19 CSR 30-86.032(26) Mattress Requirements: Based on observation and interview, the facility failed to maintain one of ten mattresses in good repair. Observation in resident room #126 showed two twin beds and one mattress with no sheets, pillow case, or blanket and the mattress was covered with large brown stains.
19 CSR 30-86.032(30) Towel & Washcloth Requirements: Based on observation and interview, the facility failed to ensure all residents had a clean hand towel and hand soap. Observations showed resident rooms (including #126, #118, and #110) had no hand towel, paper towel, or hand soap at the large counter/sink areas.
Report Facts
mattresses found deficient: 1
housekeepers on duty during the day: 1
Inspection Report — Apr 23, 2025
Routine
Date: Apr 23, 2025
Visit Reason
Missouri state licensure survey (State Form); the survey type is not stated.
Findings
Nine state licensure deficiencies were cited covering fire inspection access and inspection rights, locked exit doors preventing egress, non‑working exit sign illumination, missing sprinkler escutcheon rings, non‑flame‑resistant curtains/window coverings, use of unapproved plastic wastebaskets, improper oxygen cylinder storage, building disrepair (sheetrock hole), and electrical wiring hazards.
Deficiencies (9)
19 CSR 30-86.022(2)(D) Inspection Rights, No Fire Hazard: Based on observation and interview, the facility failed to permit inspection of portions of the building, preventing a Division of Fire and Safety inspector from accessing the men's nursing station restroom; the facility census was 54 and all residents were affected.
19 CSR 30-86.022(7)(E) Locked Exit Doors Exits, Stairways, and Fire Escapes.: Based on observation and interview, the facility failed to maintain exit door locks so they would not require a key or special knowledge to unlock from the inside; a key‑operated deadbolt on the east exit door was locked with no key present, preventing egress.
19 CSR 30-86.022(8)(C) Exit Sign-Illumination Exit Signs.: The facility failed to maintain exit lighting in good repair; the exit light located above the exit door from the FCC wing did not function when tested.
19 CSR 30-86.022(11)(A) Complete Sprinkler System-NFPA 13 Sprinkler Systems.: Sprinkler escutcheon rings were missing at multiple sprinkler heads, leaving open spaces between the finished ceiling and the sprinkler head pipe in numerous rooms and storage areas.
19 CSR 30-86.022(13)(D) Curtains/Drapes, Flame Resistant: The facility failed to ensure curtains and drapes were certified or treated to be flame‑resistant; cloth sheets and bed comforters were being used as window coverings in multiple resident rooms and no documentation of flame‑resistant treatment was found.
19 CSR 30-86.022(15)(A) Wastebaskets, Metal/UL/FM-Requirements Trash and Rubbish Disposal.: The facility used unapproved plastic wastebaskets for trash in numerous resident rooms and common areas instead of metal or UL/FM‑rated wastebaskets.
19 CSR 30-86.022(17) Oxygen Storage Requirements: The facility failed to store portable oxygen cylinders in accordance with NFPA 99; oxygen cylinders were observed standing upright and unsecured in several locations.
19 CSR 30-86.032(2) Substantially Constructed & Maintained: The facility failed to maintain the building in good repair; a three‑inch by five‑inch hole in the sheetrock wall above the countertop in resident room 112 left the interior wall exposed.
19 CSR 30-86.032(13) Electrical Wiring, Maintained, Inspected: The facility failed to properly maintain electrical wiring in good repair; an unapproved multi‑plug adapter and an unapproved extension cord were observed in use and an electrical panel was missing its dead‑front protective cover exposing live wiring.