3 Reports
Inspection Report — May 14, 2026
Life Safety
Date: May 14, 2026
Visit Reason
The Office of the State Fire Marshal conducted a scheduled fire safety inspection at the facility.
Findings
All violations noted during previous related inspections have been corrected. The facility was approved following this inspection.
Inspection Report — Apr 29, 2026
Complaint Investigation
Date: Apr 29, 2026
Visit Reason
The inspection was conducted as an unannounced on-site complaint investigation triggered by allegations that the facility failed their life and safety inspections.
Complaint Details
The complaint investigation (Complaint #221646) found that the facility failed their life and safety inspections. The Executive Director confirmed initial issues were corrected but one fire safety violation remained uncorrected as of the inspection date.
Findings
The facility was found to be out of compliance with fire safety regulations due to a damaged automatic fire-extinguishing pull station suppression system in the kitchen. The Executive Director stated that some issues were corrected, but one remained unresolved at the time of inspection.
Deficiencies (1)
WAC 388-78A-2040 Other requirements. The facility failed to maintain compliance with the Washington State Patrol Fire Protection Bureau as the Deputy State Fire Marshal found continued violation of fire codes on reinspection, specifically a damaged automatic fire-extinguishing pull station suppression system in the kitchen.
Report Facts
Total residents: 49
Employees mentioned
| Name | Title | Context |
|---|---|---|
| Krista Connelly | Community Nurse Consultant | Investigator who conducted the complaint investigation |
| Staff A | Executive Director | Named in interview regarding correction status of fire safety deficiencies |
Inspection Report — Apr 22, 2026
Life Safety
Date: Apr 22, 2026
Visit Reason
The Office of the State Fire Marshal conducted a scheduled fire protection inspection at the Eagle Springs SR Alzheimers Community facility.
Findings
The inspection identified multiple fire safety deficiencies, most of which were corrected on site. However, the facility's pull station for the kitchen suppression system was found damaged and remains uncorrected. The overall approval status is Disapproved.
Deficiencies (15)
IFC 310.7 2021 - Lighted matches, cigarettes, cigars, or other burning objects shall not be discarded in a manner that could cause ignition of other combustible material.
IFC 603.5 2021 - Relocatable power taps and current taps shall be constructed and used in accordance with NFPA 70 and this code.
IFC 606.3.3 2021 - Hoods, grease-removal devices, fans, ducts and other appurtenances shall be cleaned at required intervals.
IFC 606.4 2021 - Gas-fired commercial cooking appliances on casters must be connected to piping systems with compliant appliance connectors and limited movement by restraining devices.
IFC 701.6 2021 - The owner must maintain an inventory of required fire-resistance-rated construction and ensure annual inspection and repair of such construction.
IFC 705.2.4 2021 - Swinging fire doors shall close from the full-open position and latch automatically.
NFPA 25 13.7.2 - The facility was unable to provide documentation that the annual forward flow test of the sprinkler system had been performed.
IFC 904.13.5.2 2021 - Automatic fire-extinguishing systems shall be serviced at least every six months and after activation, with certificates forwarded to the fire code official. The facility's kitchen suppression system pull station was damaged.
IFC 906.2 2021 - Portable fire extinguishers shall be selected, installed, and maintained per NFPA 10 requirements.
IFC 907.4.2.6 2021 - Manual fire alarm boxes shall be provided with ready access, unobstructed and visible at all times.
IFC 907.8 2021 - Maintenance and testing schedules and procedures for fire alarm and detection systems shall be maintained with records of inspection, testing, and maintenance.
IFC 1010.1.9.7 2021 WAC 51-54A - Electric locking systems in Group I-1 and I-2 occupancies shall permit egress and meet specified requirements for unlocking and emergency operation.
IFC 1032.2 2021 - Required exit accesses, exits, and exit discharges shall be continuously maintained free from obstructions or impediments to full instant use in emergencies.
IFC 1203.4 2021 - Emergency and standby power systems shall be maintained to supply service within the specified time for the type and duration required.
WAC 212-12-044 - At least twelve planned and unannounced fire drills shall be held annually, with quarterly drills on each shift and monthly drills in certain groups, with detailed records maintained.
Report Facts
Next inspection scheduled: May 22, 2026