Inspection Reports for
Pruitthealth – Bethany

466 SOUTH GRAY STREET, MILLEN, GA, 30442

Back to Facility Profile

11 Reports

2018–2025

Inspection Report — Jul 1, 2025

Date: Jul 1, 2025

Visit Reason
The document is a Statement of Deficiencies and Plan of Correction for PRUITTHEALTH - BETHANY, indicating a regulatory inspection was conducted.

Findings
The report contains initial comments but does not provide detailed findings or deficiencies.

Inspection Report — May 8, 2025

Annual Inspection
Date: May 8, 2025

Visit Reason
A State Licensure survey was conducted from May 5, 2025, through May 8, 2025, to assess compliance with state health regulations at Pruitthealth Bethany.

Findings
The survey identified deficiencies including failure to maintain infection control during medication administration for one resident and failure to document consent or refusal for influenza and pneumococcal vaccines for three residents, potentially increasing their risk of infection.

Deficiencies (2)
Failure to ensure infection control during medication administration, including handling pills with bare hands and not discarding dropped pills.
Failure to offer or document consent/refusal for influenza and pneumococcal vaccines for three residents, increasing risk of influenza and pneumonia.
Report Facts
Residents observed for infection control: 3 Residents with vaccine consent/refusal documentation issues: 3 Sample residents reviewed for vaccine documentation: 23

Employees mentioned
NameTitleContext
Director of NursingDirector of NursingProvided expectations regarding medication administration and vaccine consent procedures
Licensed Practical Nurse 5Licensed Practical NurseObserved administering medication improperly by handling pills with bare hands
Registered Nurse-Clinical Competency CoordinatorRegistered Nurse-Clinical Competency CoordinatorProvided information regarding flu and pneumococcal vaccine documentation
Registered Nurse 1Registered NurseDescribed admission process for vaccination documentation

Inspection Report — Nov 14, 2023

Date: Nov 14, 2023

Visit Reason
The document is a Statement of Deficiencies and Plan of Correction related to a healthcare facility inspection conducted at PruittHealth - Bethany.

Findings
The report contains a summary statement of deficiencies identified during the inspection; however, no specific deficiencies or findings are detailed in the provided page.

Inspection Report — Sep 28, 2023

Annual Inspection
Date: Sep 28, 2023

Visit Reason
A State Licensure survey was conducted at Pruitthealth-Bethany from September 25, 2023 through September 28, 2023 to assess compliance with state health regulations.

Findings
The facility failed to ensure residents' rooms and bathrooms were safe and maintained, with multiple maintenance issues including missing threshold strips, missing baseboards, rusted assistive devices, rust-colored substances on toilets and faucets, peeling paint on heaters, holes in floors, buckling doors, and broken or missing bathroom tiles.

Deficiencies (9)
Missing threshold strips on one or both sides of bathroom entrances in multiple resident rooms creating uneven surfaces.
Missing baseboards in resident rooms 101, 103, and 127.
Over the toilet assistive device in disrepair with rust-colored substance on all four legs.
Bathroom toilets with rust-colored substance covering the inside surface in several resident rooms.
Bathroom sink faucets rusted and/or constantly dripping in multiple resident rooms.
Rust-colored heaters on walls with peeling paint in multiple resident rooms.
Holes in floors filled with white caulking where old heaters were removed in rooms 121 and 123.
Doors buckling with loose laminate and sharp edges, including holes in bathroom doors.
Broken or missing bathroom tiles in several resident rooms.
Report Facts
Rooms with deficiencies: 24 Work orders pending: 25 Sinks needing replacement: 10

Employees mentioned
NameTitleContext
Maintenance DirectorProvided statements regarding temporary fixes, condition of facility, and number of sinks needing replacement.

Inspection Report — Jun 23, 2022

Date: Jun 23, 2022

Visit Reason
The document is a statement of deficiencies and plan of correction for the facility PRUITTHEALTH - BETHANY, indicating a regulatory inspection was conducted.

Findings
The report contains initial comments and a summary statement of deficiencies, but no specific deficiencies or findings are detailed in the provided page.

Inspection Report — Apr 14, 2022

Original Licensing
Date: Apr 14, 2022

Visit Reason
A Licensure Survey was conducted from 04/11/22 through 04/14/22 to assess compliance with licensure requirements.

Findings
The facility failed to ensure proper consistency of pureed meats for nine residents on pureed texture diets, posing a choking risk and potentially decreasing resident intake. The pureed food was observed to be dry, flaky, and not smooth as required.

Deficiencies (1)
Failure to ensure proper consistency of pureed meats for nine residents on pureed texture diets, resulting in a product that was dry, flaky, and not smooth.
Report Facts
Residents on pureed texture diets: 9

Employees mentioned
NameTitleContext
Dietary ManagerDietary ManagerProvided information about the broken Robot Coupe and pureed food preparation
Dietary Aide 1Dietary AideObserved pureeing diced chicken with a small blender
Speech TherapistSpeech TherapistProvided observations on resident swallowing and pureed food texture
Certified Nurse Aide 2Certified Nurse AideAssisted resident with pureed meal and commented on food texture

Inspection Report — Nov 3, 2020

Date: Nov 3, 2020

Visit Reason
The document is a statement of deficiencies and plan of correction for the facility PRUITTHEALTH - BETHANY, indicating a regulatory inspection was conducted.

Findings
The report contains initial comments and a summary statement of deficiencies, but no specific deficiencies or findings are detailed in the provided page.

Inspection Report — Aug 28, 2020

Renewal
Date: Aug 28, 2020

Visit Reason
A Licensure Survey was conducted from 8/18/2020 through 8/28/2020 to assess compliance with safety regulations and proper use of assist rails and equipment in the facility.

Findings
The facility failed to provide an environment free from the risk of entrapment between the assist rail and air mattress for one resident, resulting in a fatality, and failed to obtain informed consent or attempt alternative methods for the use of assist rails for 12 of 13 residents. Multiple deficiencies were found related to documentation, assessment, and safety monitoring of assistive devices and bedrails.

Deficiencies (6)
Failure to provide an environment free from risk of entrapment between assist rail and air mattress for one resident resulting in death.
Failure to obtain informed consent and attempt alternative methods for use of assist rails for 12 of 13 residents.
Lack of documentation of physician orders, assessments, and care plans for assist rails prior to use.
Failure to complete timely Restraint-Adaptive Equipment Use Assessments and document alternatives to assist rails.
Inadequate communication and documentation processes for ordering, delivering, and installing assistive devices and bedrails.
Maintenance department lacked tracking system for modified beds and equipment, leading to residents being placed in beds with inappropriate equipment.
Report Facts
Residents with assist rails lacking informed consent: 12 Residents assessed with assist rails: 13 Dates of survey: Survey conducted from 2020-08-18 through 2020-08-28

Employees mentioned
NameTitleContext
LPN EELicensed Practical NurseStated expectation for staff to be alert to resident environment concerns and report immediately.
Hospice RN SSHospice Registered NursePrimary nurse for resident #1, made equipment recommendations, did not request assist rails or bariatric bed, and did not report safety concerns.
Social Services (SS)Social Services StaffAssisted with resident #1's room move, did not observe concerns with assist rails or bariatric bed.
LPN HHLicensed Practical NurseSigned for low air flow mattress delivery, did not verify correct mattress size or notify maintenance.
CNA AACertified Nursing AssistantProvided care to resident #1, observed bedrails and mattress but did not report concerns.
CNA BBCertified Nursing Assistant in trainingFound resident #1 on floor, alerted charge nurse, had no training on bedrails safety.
RN FFRegistered NurseResponded to resident #1 fall, observed gap between mattress and assist rail.
RN JJAgency Rapid Response NurseAssigned to resident #1's hall, assisted after fall, observed gap between mattress and assist rail.
Rehab ManagerRehabilitation ManagerReported lack of documentation and process for occupational therapy assessments and equipment use.
Director of Health Services (DHS)Director of Health ServicesDescribed process failures in equipment ordering, delivery, installation, safety assessments, and care plan updates.
Maintenance DirectorMaintenance DirectorReported lack of tracking system for modified beds and equipment, monthly bed inspections do not track care plans or orders.

Inspection Report — Aug 15, 2019

Routine
Date: Aug 15, 2019

Visit Reason
Licensure survey of the facility.

Complaint Details
Complaint Intakes GA00198246 and GA00196853 were investigated in conjunction with the standard survey and were unsubstantiated.
Findings
No deficiencies were identified during the Licensure Survey.

Inspection Report — May 24, 2018

Routine
Date: May 24, 2018

Visit Reason
Licensure survey to determine compliance with State Long Term Care Requirements.

Findings
During the licensure survey no State Health deficiencies were cited.

Report — October 27, 2025

October 27, 2025

36 CMS Surveys

Inspection Report — Jul 1, 2025

Follow-Up
Date: Jul 1, 2025

Visit Reason
A revisit survey was conducted from 6/30/2025 to 7/1/2025 to verify correction of deficiencies cited in the 5/8/2025 recertification survey with complaints.

Findings
All deficiencies cited as a result of the 5/8/2025 recertification survey with complaints were found to be corrected during the 6/30/2025-7/1/2025 revisit.

Inspection Report — Jul 1, 2025

Follow-Up
Date: Jul 1, 2025

Visit Reason
On July 1, 2025, a Follow-Up Survey was conducted to verify previously cited survey tags had been corrected.

Findings
A Follow-Up Survey on 2025-07-01 found that all previously cited survey tags had been corrected.

Inspection Report — May 19, 2025

Life Safety
Date: May 19, 2025

Visit Reason
Life Safety Code Survey conducted on May 19, 2025 to assess compliance with 42 CFR Subpart 483.90(a) and NFPA 101 Life Safety Code.

Findings
The facility was cited for two Life Safety Code deficiencies for unclean sprinkler heads under the front porch roof and for power strips on the floor in the activities office.

Deficiencies (2)
K 0353 - NFPA 101 Sprinkler System - Maintenance and Testing: sprinkler heads under the front porch roof area were full of dirt and dust, affecting 15 individuals in the affected area.
K 0511 - NFPA 101 Utilities - Gas and Electric: power strips were observed on the floor in the activities office, affecting five individuals in the affected area.

Inspection Report — May 8, 2025

Routine
Date: May 8, 2025

Visit Reason
Routine inspection of Pruitthealth - Bethany nursing home to assess compliance with regulations related to medication use, infection control, antibiotic stewardship, and vaccination policies.

Findings
The facility was found deficient in monitoring psychotropic medication behaviors, infection control during medication administration, antibiotic stewardship program implementation, and documentation of flu and pneumococcal vaccinations or refusals. All deficiencies were assessed as minimal harm with few residents affected.

Deficiencies (4)
F 0605: The facility failed to monitor targeted behaviors for the use of an antidepressant medication for one of five residents reviewed for unnecessary medications, risking unnecessary medication use.
F 0880: The facility failed to ensure infection control during medication administration for one of three residents, as a nurse touched pills with bare hands and did not discard a dropped pill, increasing infection risk.
F 0881: The facility failed to implement an antibiotic stewardship program that met current standards for two of three residents reviewed, resulting in potentially unnecessary antibiotic prescriptions.
F 0883: The facility failed to offer or document consent or refusal for influenza and pneumococcal vaccinations for three of five residents, increasing their risk of influenza and pneumonia.
Report Facts
Residents reviewed for unnecessary medications: 5 Residents sampled: 23 Residents reviewed for infection control: 3 Residents reviewed for antibiotic stewardship: 3 Residents reviewed for vaccination documentation: 5

Employees mentioned
NameTitleContext
Director of NursingDirector of NursingConfirmed no behavioral monitoring for R40 on antidepressant; confirmed infection control expectations; confirmed antibiotic stewardship deficiencies; discussed vaccination consent procedures.
LPN 5Licensed Practical NurseObserved touching pills with bare hands and placing dropped pill back into pill cup during medication administration to R20.
Registered Nurse-Clinical Competency CoordinatorRN-CCCProvided information regarding flu and pneumococcal vaccines.
Registered Nurse 1Registered NurseDescribed admission vaccination documentation process.

Inspection Report — May 8, 2025

Annual Inspection
Date: May 8, 2025

Visit Reason
A standard survey was conducted May 5–8, 2025 to assess the facility's compliance with Medicare/Medicaid regulations.

Findings
The facility was cited for 4 deficiencies: failure to monitor targeted behaviors for a psychotropic/antidepressant medication, failure to maintain infection control during medication administration, inadequate antibiotic stewardship and documentation, and failure to obtain or document consent/refusal for influenza and pneumococcal vaccines for three residents.

Deficiencies (4)
F 0605 - Monitoring of psychotropic medications: the facility failed to monitor targeted behaviors for Resident R40 while on Lexapro, with no behavioral monitoring documented in the MAR for February, March, and April 2025.
F 0880 - Medication administration infection control: during medication administration for Resident R20, LPN5 picked up a pill with a bare hand after it fell on the medication cart and placed it back into the pill cup and then administered the medications.
F 0881 - Antibiotic stewardship: the facility failed to follow its Antibiotic Stewardship Program and McGeer's criteria for Residents R13 and R15, including lack of antibiotic time-outs, missing cultures, and inadequate documentation related to antibiotic prescribing.
F 0883 - Pneumococcal/influenza vaccination consent: the facility did not offer or document consent or refusal for influenza and/or pneumococcal vaccines for Residents R13, R40, and R60.

Inspection Report — Sep 5, 2024

Follow-Up
Date: Sep 5, 2024

Visit Reason
Revisit survey conducted on September 5, 2024 to verify correction of deficiencies cited on July 11, 2024.

Findings
All deficiencies cited in the July 11, 2024 survey were verified as corrected.

Inspection Report — Jul 24, 2024

Follow-Up
Date: Jul 24, 2024

Visit Reason
Abbreviated survey to verify removal of an Immediate Jeopardy identified during a prior complaint survey; conducted July 22–24, 2024.

Findings
The facility was cited for four federal deficiencies (F 0600, F 0656, F 0689, F 0835) related to neglect, inadequate care planning for two-person assistance, failure to provide adequate bed-mobility assistance leading to a fall, and administrative oversight after Resident R1 fell during ADL care and subsequently expired. The State Survey Agency validated removal of the Immediate Jeopardy on 2024-07-12.

Deficiencies (4)
F 0600 - Free from Abuse and Neglect: CNA CC provided ADL care unassisted to Resident R1, who rolled away, fell from the bed, sustained a 14-centimeter head laceration with exposed skull, and expired at the hospital.
F 0656 - Develop/Implement Comprehensive Care Plan: the facility failed to develop an accurate person-centered care plan for Resident R1 specifying the need for two-person assistance with ADL care.
F 0689 - Free of Accident Hazards/Supervision/Devices: the facility failed to provide adequate assistance for bed mobility for Resident R1 during ADL care, resulting in a fall on 06/30/2024 and death within 50 minutes post-fall.
F 0835 - Administration: facility administration failed to ensure Resident R1 was free from neglect during ADL care, which resulted in R1 falling from the bed and expiring at the hospital.

Inspection Report — Jul 11, 2024

Complaint Investigation
Date: Jul 11, 2024

Visit Reason
The inspection was conducted due to a complaint investigation following a resident fall incident resulting in death, focusing on neglect and failure to provide adequate assistance during Activities of Daily Living (ADL) care.

Complaint Details
The investigation was triggered by a complaint regarding neglect during ADL care that led to a resident falling from bed and dying. The complaint was substantiated with findings of neglect, inadequate care planning, and failure of supervision.
Findings
The facility failed to protect a resident from neglect during ADL care, resulting in the resident falling from bed and dying shortly after. The care plan did not specify the need for two-person assistance, and staff failed to provide adequate supervision and assistance. Facility administration failed to ensure resident safety and effective oversight.

Deficiencies (4)
F 0600: The facility failed to protect a resident from neglect during ADL care, resulting in a fall with a severe head injury and death within 50 minutes post-fall.
F 0656: The facility failed to develop a comprehensive care plan specifying the need for two-person assistance with ADL care for the resident.
F 0689: The facility failed to provide adequate assistance and supervision to prevent a fall during ADL care, resulting in the resident's death.
F 0835: The facility administration failed to ensure resident safety and effective use of resources, contributing to neglect and the resident's fall and death.
Report Facts
Head laceration size: 14 Time to death post-fall: 50 Fall date: Jun 30, 2024 Survey completion date: Jul 11, 2024

Employees mentioned
NameTitleContext
CNA CCCertified Nursing AssistantNamed in neglect and fall incident during ADL care
LPN BBLicensed Practical NurseInterviewed regarding fall incident and resident condition
RN AARegistered Nurse/Weekend SupervisorResponded to fall incident and involved in care
RN EERegistered NurseAssessed resident after fall and described injuries
CNA DDHospice Certified Nursing AssistantProvided care to resident and described assistance needs
Administrator HHAdministratorOversight failure and interview regarding incident and staff suspension
LPN FFLicensed Practical Nurse/Case Mix DirectorInterviewed about care plan and resident assistance needs

Inspection Report — Jul 11, 2024

Complaint Investigation
Date: Jul 11, 2024

Visit Reason
Abbreviated/Partial Extended Survey investigating complaint GA00248212, which was substantiated.

Complaint Details
Complaint GA00248212 was substantiated.
Findings
The abbreviated/partial extended survey investigating complaint GA00248212 (substantiated) cited four immediate-jeopardy level deficiencies (F600, F656, F689, F835) for failure to protect a resident from neglect during ADL care, failure to develop a care plan specifying two-person assistance, failure to provide adequate assistance resulting in a fall and death, and failure of administration oversight.

Deficiencies (4)
F 0600 - Freedom from Abuse and Neglect: the facility failed to protect the resident's right to be free from neglect by staff for one of five sampled residents (R1); CNA CC provided ADL care unassisted, R1 rolled away, fell from the bed, sustained a large (14 cm) head laceration exposing skull, was transferred to the emergency department unconscious and expired at the hospital 50 minutes post-fall.
F 0656 - Develop/Implement Comprehensive Care Plan: the facility failed to develop an accurate person-centered comprehensive care plan for one of five sampled residents (R1) that specified the need for two-person assistance with Activities of Daily Living (ADL) care, despite the MDS documenting the resident required two or more helpers.
F 0689 - Free of Accident Hazards/Supervision/Devices: the facility failed to provide adequate assistance for bed mobility for one of five residents (R1) reviewed for falls; R1 fell from the bed during ADL care on 6/30/2024 resulting in injuries and death within 50 minutes post-fall.
F 0835 - Administration: facility administration failed to ensure one of five sampled residents (R1) was free from neglect during ADL care, failed to effectively oversee areas included in their job descriptions, and suspended CNA CC pending investigation after the incident.

Inspection Report — Nov 14, 2023

Follow-Up
Date: Nov 14, 2023

Visit Reason
A revisit survey was conducted on 11/13/23 through 11/14/23.

Findings
All deficiencies cited as a result of the 9/28/23 survey were found to be corrected.

Inspection Report — Nov 13, 2023

Follow-Up
Date: Nov 13, 2023

Visit Reason
On 11/13/2023 a Follow-Up Survey was conducted by this FSCO and it was noted that all previously cited survey tags have been corrected.

Findings
A follow-up survey on 11/13/2023 found that all previously cited survey tags had been corrected.

Inspection Report — Sep 28, 2023

Annual Inspection
Date: Sep 28, 2023

Visit Reason
A standard survey was conducted September 25-28, 2023 to assess compliance with Medicare/Medicaid regulations, with Complaint Intake Numbers GA00235237, GA00235306, and GA00235340 investigated in conjunction with the survey.

Complaint Details
Complaint Intake Numbers GA00235237, GA00235306, and GA00235340 were investigated and were found to be unsubstantiated.
Findings
The facility was cited for 2 deficiencies: unsafe/poorly maintained resident rooms and bathrooms in multiple rooms, and missing physician orders for oxygen administration and for tracheostomy size/type for specified residents.

Deficiencies (2)
F 0584 - Environment/maintenance: the facility failed to ensure residents' rooms and bathrooms were safe and maintained in 24 of 53 rooms observed (rooms 101, 102, 103, 104, 105, 106, 107, 108, 110, 112, 115, 117, 118, 119, 120, 121, 122, 123, 124, 126, 127, 128, 130 and 132) including missing threshold strips, missing baseboards, rusted fixtures and toilets, dripping/rusted faucets, broken or missing tiles, buckling doors with loose laminate and sharp edges, holes in floors patched with caulking, and rust-colored/heaters with peeling paint.
F 0695 - Physician orders/admission orders: the facility failed to have a physician order for oxygen administration or monitoring for Resident R66 and failed to have a physician order documenting the size and type of the tracheostomy appliance for Resident R81.

Inspection Report — Sep 28, 2023

Routine
Date: Sep 28, 2023

Visit Reason
The inspection was conducted to assess the facility's compliance with safety, environmental maintenance, and respiratory care regulations.

Findings
The facility failed to maintain residents' rooms and bathrooms in a safe and homelike condition, with multiple maintenance issues observed in 24 of 53 rooms. Additionally, the facility lacked physician orders for oxygen administration and tracheostomy size/type for two residents, posing risks to their respiratory care.

Deficiencies (2)
F 0584: The facility failed to ensure residents' rooms and bathrooms were safe and maintained in 24 of 53 rooms, including missing threshold strips, missing baseboards, rusted assistive devices, rust-colored substances on toilets and faucets, rusted heaters with peeling paint, holes in floors, and damaged doors.
F 0695: The facility failed to have a physician order for administering oxygen for one resident and failed to have a physician order for the tracheostomy size and type for another resident, placing them at risk for respiratory complications.
Report Facts
Rooms with maintenance issues: 24 Work orders pending: 25 Sinks needing replacement: 10 Residents reviewed for oxygen and tracheostomy care: 2

Employees mentioned
NameTitleContext
Maintenance DirectorProvided information about maintenance issues and work orders
Licensed Practical Nurse 2Confirmed absence of physician order for oxygen for resident R66
Director of NursingConfirmed absence of physician orders for oxygen and tracheostomy care for residents R66 and R81
Minimum Data Set CoordinatorConfirmed absence of physician orders for tracheostomy size and type

Inspection Report — Sep 27, 2023

Life Safety
Date: Sep 27, 2023

Visit Reason
Life Safety Code Survey conducted on 09/27/2023 to assess compliance with 42 CFR Subpart 483.90(a) and the NFPA 101 Life Safety Code.

Findings
The facility was cited for 7 life-safety/fire-related deficiencies including obstructions to means of egress, corridor obstructions, an exit discharge blockage, fire alarm battery marking issues, sprinkler system and piping problems, smoke barrier sealing deficiencies, and electrical hazards.

Deficiencies (7)
K 0211 - Means of Egress - General: During a tour on 09/27/2023 a wheelchair was observed blocking fire doors and a patient room privacy curtain prevented proper closing and latching.
K 0232 - Aisle, Corridor, or Ramp Width: During a tour on 09/27/2023 items, including patient scales, were stored in the corridor/nursing station common area obstructing the corridor.
K 0271 - Discharge from Exits: During a tour on 09/27/2023 a chair was blocking the chapel exit discharge leading to the public way.
K 0341 - Fire Alarm System - Installation: During a tour on 09/27/2023 observation revealed that the fire alarm batteries are marked with manufactured date, month and year.
K 0353 - Sprinkler System - Maintenance and Testing: During a tour on 09/27/2023 sprinkler head flow was observed being obstructed by a fixture/object in the riser room.
K 0372 - Subdivision of Building Spaces - Smoke Barrier: During a tour on 09/27/2023 sprinkler piping penetrations were not properly sealed and A/C duct work was sealed with foam in the nursing station common area.
K 0511 - Utilities - Gas and Electric: During a tour on 09/27/2023 multiple electrical hazards were observed including multi-tap power strips on the floor, a kitchen disconnect with exposed wires, and J-boxes missing covers in the infirmary and nursing common area attic.

Inspection Report — Apr 19, 2022

Life Safety
Date: Apr 19, 2022

Visit Reason
A review of the facility's Emergency Preparedness Program and a Life Safety Code survey were conducted on 04/19/2022.

Findings
The Emergency Preparedness Program review found the plan in compliance with 42 CFR § 483.73, and the Life Safety Code survey found the facility in compliance; no deficiencies were cited.

Inspection Report — Apr 14, 2022

Annual Inspection
Date: Apr 14, 2022

Visit Reason
A standard survey was conducted at Pruitthealth - Bethany from 04/11/2022 through 04/14/2022 to assess compliance with Medicare/Medicaid regulations.

Findings
The facility was cited for five deficiencies involving medication self-administration assessment, encoding/transmission of MDS assessments, maintenance of nutritional status, respiratory/tracheostomy care and supplies, and improper pureed food consistency.

Deficiencies (5)
F 0554 - Resident Self-Admin Meds: the facility failed to ensure one of 24 sampled residents (R14) had a physician's order and was screened/assessed for self-administration or bedside medication storage prior to medications being stored at the bedside and self-administered.
F 0640 - Encoding/Transmitting Resident Assessments: the facility failed to encode and transmit MDS assessments for 2 of 2 residents reviewed for resident assessment (R1 and R2), with R1's assessment not completed and R2's quarterly MDS in 'Early - In Process' status past the completion due date.
F 0692 - Nutrition/Hydration Status Maintenance: the facility failed to maintain acceptable nutritional parameters for 1 of 1 resident reviewed for nutrition (R18), who experienced continued significant weight loss (e.g., weights noted 96 lbs on 03/16/22 and 86 lbs on 04/13/22) with no recent RD reassessments documented.
F 0695 - Respiratory/Tracheostomy Care and Suctioning: the facility failed to maintain oxygen equipment (undated/unclean tubing, water bottles, and concentrator filters; tubing not stored in clear bags) for 3 of 4 residents reviewed for respiratory therapy (R19, R43, R47) and failed to maintain an emergency tracheostomy kit at bedside for 1 of 1 resident with a tracheostomy (R7).
F 0805 - Food in Form to Meet Individual Needs: the facility failed to provide properly textured pureed meats for nine residents on pureed diets (of 78 census residents), with purees observed to be dry, flaky, or contain small chunks rather than a smooth consistency.

Inspection Report — Apr 14, 2022

Complaint Investigation
Date: Apr 14, 2022

Visit Reason
The inspection was conducted based on complaints regarding medication self-administration without assessment, late Minimum Data Set (MDS) transmissions, nutritional status concerns, respiratory equipment maintenance, tracheostomy emergency kit readiness, and food texture consistency.

Complaint Details
The visit was complaint-related, triggered by allegations of medication self-administration without assessment, late MDS transmissions, nutritional concerns, respiratory equipment maintenance failures, emergency tracheostomy kit deficiencies, and improper food texture.
Findings
The facility failed to assess and order medication self-administration for a resident, delayed encoding and transmission of MDS assessments for two residents, inadequately maintained nutritional status for one resident with significant weight loss, failed to maintain oxygen and respiratory equipment properly for multiple residents, lacked proper emergency tracheostomy supplies for one resident, and provided improperly textured pureed foods for residents on pureed diets.

Deficiencies (5)
F 0554: The facility failed to ensure one resident had a physician's order and assessment for self-administration of medications prior to bedside storage and self-administration, creating potential for medication errors.
F 0640: The facility failed to encode and transmit Minimum Data Set assessments timely for two residents, risking delays in payor notifications.
F 0692: The facility failed to maintain acceptable nutritional parameters for one resident, resulting in continued significant weight loss.
F 0695: The facility failed to maintain oxygen equipment and emergency tracheostomy supplies properly for multiple residents, risking respiratory infection, distress, and emergency response delays.
F 0805: The facility failed to provide pureed meats with proper smooth consistency for nine residents, creating choking risk and decreased intake.
Report Facts
Residents on pureed texture diets: 9 Weight loss percentage: 10.4 BIMS score: 15 BIMS score: 6 Oxygen flow rate: 2 Oxygen flow rate: 2.5 Oxygen flow rate: 5

Employees mentioned
NameTitleContext
LPN1Licensed Practical NurseProvided tracheostomy care and reported missing ambu bag in emergency kit
LPN2Licensed Practical NurseConfirmed oxygen equipment maintenance deficiencies for resident R43
Director of NursingDirector of NursingConfirmed awareness of medication self-administration issue and oxygen equipment maintenance failures
Dietary ManagerDietary ManagerReported broken Robot Coupe blender affecting pureed food texture
Speech TherapistSpeech TherapistObserved and commented on pureed food texture and resident swallowing
Certified Nursing Assistant 2Certified Nursing AssistantAssisted resident with pureed meal and noted food texture issues
Certified Nursing Assistant 1Certified Nursing AssistantConfirmed resident self-administered medication without assessment
Skin Integrity Coordinator Registered NurseRegistered NurseConfirmed oxygen equipment deficiencies for resident R19
Case Mix Director 1Case Mix DirectorAcknowledged late MDS assessments
Case Mix Director 2Case Mix DirectorAcknowledged late MDS assessments

Inspection Report — Nov 3, 2020

Follow-Up
Date: Nov 3, 2020

Visit Reason
Revisit to verify correction of deficiencies cited during the August 28, 2020 Complaint Survey.

Findings
A revisit survey conducted on November 3, 2020 found that all deficiencies cited as a result of the August 28, 2020 Complaint Survey were corrected.

Inspection Report — Aug 28, 2020

Complaint Investigation
Date: Aug 28, 2020

Visit Reason
Abbreviated/Partial Extended Survey to investigate complaint intakes GA00207476 (substantiated) and GA00203326 (unsubstantiated).

Complaint Details
Complaint intake #GA00207476 was substantiated with deficiencies. Complaint intake #GA00203326 was unsubstantiated.
Findings
The facility was cited for failures in comprehensive care planning and bedrail/assistive device management after a resident was found with head entrapped between a mattress and assist rail; deficiencies included lack of a care plan for assist rails for one resident and failures to assess entrapment risk, ensure mattress/rail compatibility, obtain informed consent, and attempt alternatives for multiple residents.

Deficiencies (2)
F 0656 - Develop/Implement Comprehensive Care Plan: the facility failed to develop and implement a care plan for assist rails for one resident (R#1) of 13 residents with bedrails.
F 0700 - Bedrails: the facility failed to assess entrapment risk, ensure correct mattress/bed dimensions and installation, and obtain informed consent or attempt alternatives prior to use — R#1 was placed on a bariatric bed with a standard low air loss mattress leaving a gap between mattress and assist rail and 12 of 13 residents lacked documented informed consent/alternatives.

Inspection Report — Jul 31, 2020

Life Safety
Date: Jul 31, 2020

Visit Reason
A COVID-19 Focused Emergency Preparedness Survey and a COVID-19 Focused Infection Control Survey were conducted by Ascellon on behalf of the Georgia Department of Community Health on July 30-31, 2020.

Findings
The facility was found to be in compliance with emergency preparedness and infection control regulations (42 CFR §483.73 and 42 CFR §483.80) during the July 30-31, 2020 surveys.

Inspection Report — Jun 29, 2020

Life Safety
Date: Jun 29, 2020

Visit Reason
A COVID-19 Focused Emergency Preparedness Survey and a COVID-19 Focused Infection Control Survey were conducted on June 29, 2020 to assess the facility's preparedness and infection control related to COVID-19.

Findings
The facility was found to be in compliance with 42 CFR §483.73 related to emergency preparedness and in compliance with 42 CFR §483.80 infection control; no deficiencies were cited.

Inspection Report — Feb 10, 2020

Complaint Investigation
Date: Feb 10, 2020

Visit Reason
An unannounced Abbreviated/Partial Extended Survey was conducted to investigate complaint #GA00202635.

Complaint Details
Complaint GA00202635 was investigated; no deficiencies were cited.
Findings
The complaint investigation was conducted on February 10, 2020 and no deficiencies were cited.

Inspection Report — Oct 9, 2019

Follow-Up
Date: Oct 9, 2019

Visit Reason
Follow up to the Recertification survey of August 15, 2019 conducted on October 9, 2019.

Findings
The follow-up survey revealed that all deficiencies cited in the August 15, 2019 recertification survey were corrected and the facility was in substantial compliance as of September 29, 2019.

Inspection Report — Oct 1, 2019

Follow-Up
Date: Oct 1, 2019

Visit Reason
Follow-up survey conducted by the FSCO on 10/01/2019 to verify correction of previously cited deficiencies.

Findings
A review of the facility's Emergency Preparedness plan on 10/01/2019 found the plan to be in substantial compliance, and the follow-up survey noted that all previously cited survey tags had been corrected.

Inspection Report — Aug 15, 2019

Routine
Date: Aug 15, 2019

Visit Reason
Licensure survey of the facility.

Complaint Details
Complaint Intakes GA00198246 and GA00196853 were investigated in conjunction with the standard survey and were unsubstantiated.
Findings
No deficiencies were identified during the Licensure Survey.

Deficiencies (1)
F 0645 - PASARR screening: the facility failed to ensure Resident #47 had a PASRR Level II review completed prior to admission; the resident sample was 31.

Inspection Report — Aug 14, 2019

Life Safety
Date: Aug 14, 2019

Visit Reason
During a Life Safety Code Survey conducted on 08/14/2019, Pruitt Health - Bethany was evaluated for compliance with 42 CFR Subpart 483.70(a) and NFPA 101 Life Safety Code requirements.

Findings
The facility was cited for 5 Life Safety Code deficiencies including a detached handrail at an exit stairwell, missing ceiling tiles in the telephone/IT room, a smoke detector positioned within 3 feet of an HVAC discharge vent in the oxygen room, painted sprinkler heads in the kitchen back hall, and an employee unable to locate the smoking policy.

Deficiencies (5)
K 0227 - Ramps and Other Exits: observation revealed the handrail was no longer attached to the exit stairwell wall outside the exit door from the Nurses Station and was off and laying on the stairs.
K 0311 - Vertical Openings - Enclosure: observation revealed that ceiling tiles in the telephone room (IT closet) were missing from the grid.
K 0342 - Fire Alarm System - Initiation: observation revealed the smoke detector in the oxygen room was within 3 feet of an HVAC discharge vent.
K 0353 - Sprinkler System - Maintenance and Testing: observation revealed painted sprinkler heads in the back hall of the kitchen.
K 0741 - Smoking Regulations: during a tour and interview, an employee at the nurses station desk was not able to tell where the facility smoking policy was located.

Inspection Report — Mar 7, 2019

Complaint Investigation
Date: Mar 7, 2019

Visit Reason
An Abbreviated/Partial Extended Survey investigating complaint GA00194933 was conducted on March 6, 2019 to March 7, 2019.

Complaint Details
Complaint GA00194933 was unsubstantiated with no deficiencies.
Findings
The complaint was unsubstantiated with no deficiencies.

Inspection Report — Oct 30, 2018

Complaint Investigation
Date: Oct 30, 2018

Visit Reason
An Abbreviated/Partial Extended Survey was conducted to investigate complaint GA00191418 on October 30, 2018.

Complaint Details
Complaint GA00191418 was unsubstantiated with no deficiencies.
Findings
The complaint was unsubstantiated with no deficiencies cited.

Inspection Report — Jul 13, 2018

Follow-Up
Date: Jul 13, 2018

Visit Reason
Follow-Up Survey to verify that previously cited survey tags were corrected.

Findings
The follow-up survey on 2018-07-13 noted that all previously cited survey tags had been corrected.

Inspection Report — Jul 9, 2018

Follow-Up
Date: Jul 9, 2018

Visit Reason
Revisit survey to verify corrections to deficiencies cited during the standard survey of 05/24/2018.

Findings
A revisit survey on 07/09/2018 found that all deficiencies cited as a result of the standard survey of 05/24/2018 were corrected.

Inspection Report — May 24, 2018

Routine
Date: May 24, 2018

Visit Reason
Licensure survey to determine compliance with State Long Term Care Requirements.

Findings
During the licensure survey no State Health deficiencies were cited.

Deficiencies (1)
F 0880 - Infection Prevention & Control: the facility failed to ensure staff used proper hand sanitation methods during meal service for three of three meal observations; CNAs were observed not changing gloves between beverage deliveries and not sanitizing or washing hands after touching hair, clothing, wheelchairs, or residents.

Inspection Report — May 22, 2018

Life Safety
Date: May 22, 2018

Visit Reason
Life Safety Code survey to assess compliance with NFPA 101 Life Safety Code and 42 CFR Subpart 483.70(a).

Findings
The facility was cited for 6 Life Safety Code deficiencies involving missing/defective door closers, sprinkler system maintenance issues, corridor/door closing problems, improper use/location of a power strip, mixed/incorrect oxygen cylinder storage signage, and unsecured oxygen cylinders.

Deficiencies (6)
K 0223 - NFPA 101 Doors with Self-Closing Devices: facility failed to maintain fire door closers; door closer missing for fire door in attic fire wall and missing from the Director of Nursing's office door.
K 0353 - NFPA 101 Sprinkler System - Maintenance and Testing: observations included a loaded fire sprinkler head in the dietary manager's office over the desk, sprinkler heads needing adjustment in Dee's office and the employees' restroom on Brannon Hall, an escutcheon plate missing in room 122-A's closet, and wiring on sprinkler pipes above the clean linen closet across from Brannon Nursing Station.
K 0363 - NFPA 101 Corridor - Doors: facility failed to maintain doors; fire door would not close securely coming out of the kitchen serving line exit, infirmary fire doors would not close securely, and janitor door in Brannon Hall not closing secure.
K 0920 - NFPA 101 Electrical Equipment - Power Cords and Extens: a power strip was observed on the floor under a desk in the dietary manager's office.
K 0923 - NFPA 101 Gas Equipment - Cylinder and Container Storage: oxygen cylinders were mixed empty with full and the signage on the oxygen cylinder storage room needed to be updated to the proper door signage.
K 0929 - NFPA 101 Gas Equipment - Precautions for Handling Oxyg: some oxygen cylinders in the cylinder storage closet were not secured and were free standing.

Inspection Report — Jul 6, 2017

Follow-Up
Date: Jul 6, 2017

Visit Reason
A desk review revisit was conducted on 07/06/2017 to verify correction of deficiencies from the 5/22/17 through 5/25/17 Recertification Survey.

Findings
All deficiencies cited in the 5/22/17 through 5/25/17 Recertification Survey were found to be corrected.

Inspection Report — Jun 29, 2017

Follow-Up
Date: Jun 29, 2017

Visit Reason
On 06/29/2017 a Follow-Up Survey was conducted by this FSCO to determine the status of previously cited survey tags.

Findings
The follow-up survey noted that all previously cited survey tags have been corrected.

Inspection Report — May 25, 2017

Life Safety
Date: May 25, 2017

Visit Reason
Life Safety Code survey to determine compliance with Medicare/Medicaid participation requirements and NFPA 101 Life Safety Code.

Findings
The facility was cited for 9 Life Safety Code deficiencies involving inoperable egress doors, emergency lighting failure, vertical opening/penetration, sprinkler supervisory signals and maintenance issues, corridor and resident room door defects affecting latching and smoke tightness, and improper use/placement of power strips and extension cords.

Deficiencies (9)
K 0222 - NFPA 101 Egress Doors: the egress door from the main dining room to the exterior was inoperable due to a faulty keypad and would only release if the fire alarm activated.
K 0291 - Emergency Lighting: exit light #19 failed to operate on 12 volt DC when tested.
K 0311 - Vertical Openings - Enclosure: a vertical opening (overcut) was observed in the ceiling around a sprinkler head into the attic of the Treatment Room.
K 0352 - Sprinkler System - Supervisory Signals: electrical wires and other items were observed laying on or attached to fire sprinkler piping throughout the attic.
K 0353 - Sprinkler System - Maintenance and Testing: sprinkler heads in the Dietary Office and kitchen prep area were loaded with lint and storage heights exceeded the 18-inch limit in residents' closets and the soiled utility room.
K 0363 - Corridor - Doors: the door to room 114 would not latch securely because decorations were hung over the door.
K 0371 - Subdivision of Building Spaces - Smoke Compartments: the door to room 136 had a gap at the top leading edge preventing it from being smoke tight and exceeding the 1/2 inch allowance for wood doors.
K 0511 - Utilities - Gas and Electric: power strips were not mounted off the floor and were being run over by office chairs in multiple offices (medical records and an office across from Administration).
K 0920 - Electrical Equipment - Power Cords and Extension Cords: an extension cord was found in use behind the piano in the Chapel.

Inspection Report — Apr 2, 2017

Complaint Investigation
Date: Apr 2, 2017

Visit Reason
Complaint survey to investigate complaints GA00163280 and GA00158669 at Pruitt Health Bethany.

Complaint Details
Complaints GA00163280 and GA00158669 were unsubstantiated with no deficiencies.
Findings
The complaint survey was unsubstantiated with no deficiencies cited. The facility's census on April 2 was 70 residents.