Inspection Reports for
Rehabilitation Center of South Georgia

2002 TIFT AVENUE NORTH, TIFTON, GA, 31794

Back to Facility Profile

20 Reports

2018–2026

Inspection Report — Aug 28, 2024

Date: Aug 28, 2024

Visit Reason
The document is a statement of deficiencies and plan of correction for the Rehabilitation Center of South Georgia following a survey completed on 08/28/2024.

Findings
The report contains initial comments but does not provide specific details on deficiencies or findings.

Inspection Report — Jun 25, 2024

Date: Jun 25, 2024

Visit Reason
The document is a Statement of Deficiencies and Plan of Correction for the Rehabilitation Center of South Georgia, indicating a regulatory inspection was conducted.

Findings
The report contains an initial comment section but does not provide specific findings or deficiencies in the provided page.

Inspection Report — Apr 25, 2024

Renewal
Date: Apr 25, 2024

Visit Reason
The inspection was conducted as a State Licensure survey to determine compliance with the State Long Term Care Requirements.

Findings
No State Health deficiencies were cited during the survey conducted from April 23, 2024 through April 25, 2024.

Inspection Report — Nov 9, 2023

Date: Nov 9, 2023

Visit Reason
The document is a statement of deficiencies and plan of correction for the Rehabilitation Center of South Georgia following a survey completed on November 9, 2023.

Findings
The report contains a summary statement of deficiencies identified during the survey; however, no specific deficiencies or details are provided in the available page.

Inspection Report — Sep 28, 2023

Annual Inspection
Date: Sep 28, 2023

Visit Reason
A State Licensure survey was conducted from September 6, 2023 through September 28, 2023 to determine compliance with the State Long Term Care Requirements.

Findings
The facility failed to ensure fentanyl patches were destroyed in the presence of two licensed nurses and documented on the Certificate of Inventory and Destruction for Reverse Distribution form for one resident (R#9).

Deficiencies (1)
Failure to ensure fentanyl patches were destroyed in the presence of two licensed nurses and documented for one resident (R#9).
Report Facts
Sample size: 14 Fentanyl patch dosage: 75 Dates of fentanyl patch application: 2

Employees mentioned
NameTitleContext
Director of NursingInterviewed regarding fentanyl patch disposal and in-service training

Inspection Report — Apr 12, 2023

Date: Apr 12, 2023

Visit Reason
The document is a statement of deficiencies and plan of correction for the Rehabilitation Center of South Georgia following a survey completed on April 12, 2023.

Findings
The report contains initial comments but does not provide specific details on deficiencies or findings.

Inspection Report — Feb 16, 2023

Annual Inspection
Date: Feb 16, 2023

Visit Reason
The inspection was conducted as a State Licensure survey from February 14, 2023 through February 16, 2023 to determine compliance with the State Long Term Care Requirements.

Findings
The facility failed to implement the plan of care for one resident related to activities of daily living, specifically not receiving scheduled showers and baths. Additionally, the facility failed to maintain cleanliness and sanitation of feeding pumps for three residents and failed to maintain the facility environment, including scuffed walls, stained ceiling tiles, and dusty air vents.

Deficiencies (3)
Failure to implement plan of care for resident R#267 related to activities of daily living, specifically not receiving scheduled showers and baths.
Failure to ensure feeding pumps for three residents (R#2, R#5, R#26) were clean and sanitary.
Failure to maintain facility cleanliness including scuffed walls in rooms 206, 210, 212, stained ceiling tiles and scuffed floor tile in bathroom 104, and heavy dust buildup on ceiling vents outside rooms 104 and 105.
Report Facts
Residents affected: 1 Residents affected: 3 Bath dates documented: 5

Employees mentioned
NameTitleContext
Assistant Director of NursingInterviewed confirming resident R#267 did not receive bath from 12/5/2022 through 12/14/2022
Director of NursingInterviewed regarding bath scheduling and documentation procedures
AdministratorParticipated in walk-through confirming environmental deficiencies
Environmental Services DirectorParticipated in confirmation rounds of feeding pump sanitation issues

Inspection Report — Dec 7, 2022

Date: Dec 7, 2022

Visit Reason
The document is a Statement of Deficiencies and Plan of Correction for the Rehabilitation Center of South Georgia, indicating a regulatory inspection was conducted.

Findings
No specific deficiencies or findings are detailed in the provided report.

Inspection Report — Oct 4, 2022

Abbreviated Survey
Date: Oct 4, 2022

Visit Reason
An Abbreviated/Partial Extended Survey was conducted to investigate multiple complaints against the facility, initiated on September 20, 2022 and concluded on October 4, 2022.

Complaint Details
The survey investigated complaints GA00221625, GA00221707, GA00223645, GA00225713, GA00225845, and GA00226772. Complaints GA00221625, GA00221707, and GA00223645 were unsubstantiated. Complaints GA00225713, GA00225845, and GA00226772 were substantiated with deficiencies.
Findings
Complaints GA00221625, GA00221707, and GA00223645 were unsubstantiated, while complaints GA00225713, GA00225845, and GA00226772 were substantiated with deficiencies. No State Licensure deficiencies were cited despite identified concerns.

Inspection Report — Nov 17, 2021

Date: Nov 17, 2021

Visit Reason
The document is a statement of deficiencies and plan of correction for the Rehabilitation Center of South Georgia following a survey completed on 11/17/2021.

Findings
The report contains initial comments and a summary statement of deficiencies identified during the survey; however, no specific deficiencies or severity levels are detailed in the provided page.

Inspection Report — Sep 29, 2021

Abbreviated Survey
Date: Sep 29, 2021

Visit Reason
An Abbreviated/Partial Extended Survey was conducted from September 23, 2021 to September 29, 2021, investigating multiple complaints and concerns related to resident care, abuse allegations, medication management, and wound care at the Rehabilitation Center of South Georgia.

Complaint Details
Complaints GA00215334 and GA00215460 were substantiated, while complaints GA00215472 and GA00216957 were unsubstantiated. The substantiated complaints involved failures in abuse reporting and wound care.
Findings
The facility was found to have multiple deficiencies including failure to timely report resident-to-resident altercations and abuse allegations, failure to provide privacy and dignity during care, medication carts not properly secured, and inadequate wound care with failure to follow care plans especially on weekends. Some complaints were substantiated while others were unsubstantiated.

Deficiencies (4)
Failure to timely report resident-to-resident altercations, injuries of unknown origin, and alleged staff to resident abuse for four of five reports reviewed.
Failure to provide privacy by closing window blinds during perineal care and failure to treat a resident in a dignified manner during care.
Failure to ensure two of four medication carts were locked or that locking mechanisms functioned properly.
Failure to develop a care plan for a surgical site for one resident and failure to follow wound care plans on weekends for multiple residents, including failure to provide wound care for pressure ulcers.
Report Facts
Medication carts: 2 Residents with wound care deficiencies: 4 Residents with privacy/dignity issues: 2 Residents with abuse reporting failures: 4

Employees mentioned
NameTitleContext
LPN AALicensed Practical Nurse, wound care nurseNamed in wound care deficiencies and interview regarding weekend wound care.
LPN BBLicensed Practical Nurse, wound care nurseAssisted LPN AA with wound care observation.
CNA CCCertified Nurse AideObserved providing perineal care without closing window blinds and involved in dignity issue.
CNA IICertified Nurse AideMade inappropriate comparison remark and left resident exposed during perineal care.
LPN GGLicensed Practical NurseInterviewed regarding medication cart lock malfunction.
LPN EELicensed Practical NurseInterviewed regarding failure to lock medication cart.
Director of NursingDirector of Nursing (DON)Interviewed multiple times regarding abuse reporting, privacy, medication cart security, and wound care.
AdministratorFacility AdministratorInterviewed regarding medication cart maintenance and wound care responsibilities.

Inspection Report — Mar 12, 2020

Date: Mar 12, 2020

Visit Reason
The document is a statement of deficiencies and plan of correction for the Rehabilitation Center of South Georgia following a survey completed on March 12, 2020.

Findings
The report contains initial comments and a summary statement of deficiencies identified during the survey; however, no specific deficiencies or findings are detailed in the provided page.

Inspection Report — Jan 24, 2020

Renewal
Date: Jan 24, 2020

Visit Reason
The inspection was a licensure survey conducted from January 21, 2020 through January 24, 2020 to determine compliance with State Long Term Care Requirements.

Findings
The facility failed to transport clothing from the laundry room in a sanitary manner potentially affecting 99 of 133 residents, and failed to store personal items in a sanitary manner in three of 74 resident bathrooms. Observations included uncovered plastic containers used to transport clean clothing and unlabeled, unbagged urinals and buckets in shared bathrooms.

Deficiencies (2)
Failure to transport clothing from the laundry room in a sanitary manner affecting 99 of 133 residents.
Failure to store personal items in a sanitary manner in three of 74 resident bathrooms.
Report Facts
Residents affected: 99 Total residents: 133 Resident bathrooms: 74 Bathrooms with unsanitary storage: 3

Employees mentioned
NameTitleContext
Head of HousekeepingInterviewed regarding laundry transport and storage practices.
Director of Nursing (DON)Confirmed that all clean clothing items should be covered while being transported.
Assistant Director of Nursing (ADON)Reported that urinals should be labeled and stored in a bag off the floor.

Inspection Report — Aug 9, 2018

Complaint Investigation
Date: Aug 9, 2018

Visit Reason
The inspection was conducted due to concerns regarding the facility's failure to provide adequate treatment and services to a resident (R#134) who exhibited symptoms of major depressive disorder and expressed suicidal ideations.

Complaint Details
The investigation was complaint-driven based on concerns about the facility's handling of a resident (R#134) who expressed suicidal ideations and refused psychiatric care. The resident repeatedly voiced statements about wanting to die, refused medications, and exhibited behaviors indicating depression and agitation. The facility failed to adequately respond to these behaviors, notify appropriate medical staff, or provide necessary psychiatric evaluation and treatment.
Findings
The facility failed to properly monitor and document the resident's depressive symptoms and suicidal statements, did not notify the attending physician or medical director of the resident's repeated statements about wanting to die, and failed to provide psychiatric or psychological services despite documented needs. The care plan was incomplete and did not fully address the resident's mood and behavioral issues.

Deficiencies (5)
Failure to provide treatment and services to resident with major depressive disorder who repeatedly voiced suicidal ideations.
Failure to monitor and document depressive symptoms in the Medication Administration Record as ordered.
Failure to notify attending physician or medical director of resident's suicidal statements and behaviors.
Failure to provide psychiatric or psychological services despite documented need and resident's refusal.
Failure to fully develop comprehensive care plans related to mood and behaviors for the resident.
Report Facts
Sample size: 49 BIMS score: 14 BIMS score: 10 Medication administration period: 30 Care plan target date: Oct 23, 2018

Employees mentioned
NameTitleContext
LPN KKLicensed Practical NurseHelped with orders for Cymbalta and monitoring of depression behaviors; stated nurses did not document monitoring due to electronic record issues.
RN JJRegistered Nurse, Unit 2A Patient Care CoordinatorAdded resident to psych evaluation list and provided information about telemedicine psychiatric services.
SW HHSocial WorkerEvaluated resident, noted refusal of psychiatric intervention, and acknowledged lack of documentation of refusal.
LPN IILicensed Practical NurseReported resident's refusal of supplements and dialysis and described resident's mood changes.
Medical DirectorMedical DirectorStated that resident's suicidal statements should have been reported and acted upon; confirmed expectations for staff notification.
AdministratorFacility AdministratorAcknowledged resident's statements and care challenges; stated intent to honor resident's rights.
LPN FFLicensed Practical Nurse, MDS CoordinatorAcknowledged not updating behavior care plans despite awareness of resident's suicidal remarks.
Nurse Practitioner (NP)Medical Director's Nurse PractitionerOrdered Cymbalta initially; was not informed of resident's suicidal statements; noted Cymbalta was not reordered after hospital readmission.

Inspection Report — Feb 23, 2018

Complaint Investigation
Date: Feb 23, 2018

Visit Reason
Abbreviated/Partial Extended survey investigating complaint GA00185574.

Complaint Details
Complaint GA00185574 was unsubstantiated but with deficiencies.
Findings
The State report cited the facility for failing to revise care plans to reflect the actual presence of a pressure sore for two of three sampled residents.

Deficiencies (1)
N 1018 - Medical, Dental and Nursing Care: the facility failed to revise the care plan to reflect the actual presence of a pressure sore for two (#2 and #3) of three sampled residents.

Report — February 26, 2026

February 26, 2026

Report — January 29, 2026

January 29, 2026

Report — January 29, 2026

January 29, 2026

Report — January 20, 2026

January 20, 2026

Report — August 27, 2025

August 27, 2025

50 CMS Surveys

Inspection Report — Dec 4, 2025

Routine
Date: Dec 4, 2025

Visit Reason
The inspection was conducted to assess compliance with regulatory requirements related to medication self-administration, care plan implementation, feeding tube care, and respiratory care in a nursing facility.

Findings
The facility failed to ensure secure storage of self-administered medications for three residents, proper adherence to care plans for one resident, correct feeding tube flush rates for one resident, and appropriate oxygen administration for one resident. These deficiencies posed potential risks of harm or complications to the affected residents.

Deficiencies (4)
F 0554: The facility failed to ensure three residents had unauthorized, unsecured medications at bedside, risking unauthorized access. The zinc oxide cream was found unsecured in resident rooms without physician orders or self-administration assessments.
F 0656: The facility failed to follow the care plan for one resident receiving oxygen therapy, administering oxygen at a higher flow rate than ordered, risking respiratory complications.
F 0693: The facility failed to ensure one resident receiving tube feeding was given water flushes as ordered, with the feeding pump set at 40 cc per hour instead of 50 cc, risking dehydration.
F 0695: The facility failed to provide safe and appropriate respiratory care by administering oxygen at four liters per minute instead of the ordered two liters per minute for one resident, risking adverse effects including hypercapnia.
Report Facts
Residents sampled: 36 Residents affected: 3 Residents affected: 1 Residents affected: 1 Residents affected: 1 Oxygen flow rate ordered: 2 Oxygen flow rate observed: 4 Tube feeding water flush ordered: 50 Tube feeding water flush observed: 40

Employees mentioned
NameTitleContext
DDLicensed Practical NurseConfirmed and corrected feeding pump water flush rate for resident R84
Director of NursingDirector of NursingConfirmed unsecured medications and provided staff in-services; stated expectations for tube feeding and oxygen administration compliance
Assistant Director of NursingAssistant Director of NursingObserved and corrected oxygen flow rate for resident R77
AdministratorAdministratorStated expectations for nursing staff to follow physician orders for tube feeding and flush rates

Inspection Report — Apr 9, 2025

Complaint Investigation
Date: Apr 9, 2025

Visit Reason
An Abbreviated/Partial Extended Survey investigating complaints GA00254253 and GA00254533 was initiated on 4/8/2025 and concluded on 4/9/2025.

Complaint Details
Complaints GA00254253 and GA00254533 were unsubstantiated with no regulatory violations cited.
Findings
Complaints GA00254253 and GA00254533 were unsubstantiated with no regulatory violations cited, and no deficiencies were cited as a result of this survey. The facility census was 118.

Inspection Report — Dec 12, 2024

Complaint Investigation
Date: Dec 12, 2024

Visit Reason
An Abbreviated/Partial Extended Survey was initiated to investigate complaints GA00249416, GA00249589, GA00250442, GA00251723, GA00251848, and GA00251924.

Complaint Details
Complaints GA00249416, GA00251848, and GA00251924 were unsubstantiated. Complaints GA00249589, GA00250442, and GA00251723 were substantiated.
Findings
The survey investigated six complaints; three complaints were substantiated and three were unsubstantiated, and no deficiencies were cited.

Inspection Report — Aug 28, 2024

Follow-Up
Date: Aug 28, 2024

Visit Reason
Revisit survey conducted to verify correction of deficiencies from the July 4, 2024 Recertification survey.

Findings
All deficiencies cited as a result of the July 4, 2024 Recertification survey were found to be corrected.

Inspection Report — Aug 19, 2024

Follow-Up
Date: Aug 19, 2024

Visit Reason
Follow-up survey to verify correction of previously cited survey tags.

Findings
On 2024-08-19 a follow-up survey was conducted by the FSCO and all previously cited survey tags were found to be corrected.

Inspection Report — Jul 4, 2024

Routine
Date: Jul 4, 2024

Visit Reason
Routine inspection survey conducted to assess compliance with healthcare regulations and standards at the Rehabilitation Center of South Georgia.

Findings
The facility had multiple deficiencies including failure to honor resident rights, protect residents from abuse, implement abuse policies, provide adequate transfer documentation, develop comprehensive care plans, provide adequate activities, ensure fall prevention measures, manage medications properly, maintain food safety, dispose of garbage properly, and implement infection control and antibiotic stewardship programs.

Deficiencies (17)
F 0561: Facility failed to honor resident R36's right to get out of bed due to lack of available lift pads, resulting in potential harm.
F 0600: Facility failed to protect four residents from physical abuse by another resident and did not consider some incidents as abuse.
F 0607: Facility failed to implement abuse policy related to employee screening by not checking references for three employees prior to hire.
F 0610: Facility failed to conduct thorough investigations of resident-to-resident abuse incidents for four residents, lacking witness statements.
F 0622: Facility failed to provide adequate transfer documentation for resident R86, risking incomplete care at receiving facility.
F 0623: Facility failed to notify resident R86, responsible party, and Ombudsman in writing about transfer or discharge.
F 0625: Facility failed to provide resident R86 written notice specifying duration of bed hold policy after hospital transfer.
F 0656: Facility failed to implement person-centered care plans with measurable goals for fall prevention and activity engagement for multiple residents.
F 0679: Facility failed to ensure fall prevention measures including bed position and fall mat placement for residents R43 and R84.
F 0755: Facility failed to provide pharmaceutical services ensuring availability of physician ordered medication for resident R9.
F 0756: Facility failed to ensure monthly pharmacist medication regimen reviews included antibiotic usage monitoring for resident R63.
F 0761: Facility failed to ensure medication cart was locked and medications were not left unattended, risking resident R79's access to medications.
F 0804: Facility failed to provide food at safe and appetizing temperatures during meal service, with food temperatures below acceptable levels.
F 0814: Facility failed to ensure garbage dumpsters were kept closed, exposing trash and risking pest attraction.
F 0880: Facility failed to follow infection control procedures during wound care, medication administration, and contact isolation for residents R8, R75, and R77.
F 0881: Facility failed to monitor and track antibiotic use and stewardship for resident R63, missing inappropriate antibiotic administration and lack of urology consultation.
F 0759: Facility failed to ensure medication error rate below 5%, with two errors observed for resident R77 during medication administration.
Report Facts
Medication error rate: 7.41 Deficiency count: 16

Employees mentioned
NameTitleContext
LPN 6Licensed Practical NurseAdministered wrong aspirin and touched medications with bare hands
LPN 9Licensed Practical NurseLeft medication cart unlocked with medications unattended
LPN 8Licensed Practical NurseFailed to follow proper wound care infection control procedures
RN 1Registered Nurse/Unit ManagerConfirmed fall prevention expectations and medication handling standards
Corporate NurseConfirmed medication handling policy and antibiotic stewardship gaps
AdministratorAcknowledged issues with infection control, antibiotic stewardship, and activity program
Infection PreventionistReported gaps in antibiotic stewardship and infection control practices

Inspection Report — Jul 2, 2024

Life Safety
Date: Jul 2, 2024

Visit Reason
A review of the Emergency Preparedness Program for Rehabilitation Center of South Georgia was conducted on 2024-07-02.

Findings
The facility was cited for 4 life safety deficiencies: lack of smoke detector sensitivity testing and documentation, stored items exceeding sprinkler clearance, unsealed firewall penetrations, and obstructed electrical panels; three of these were corrected during the survey.

Deficiencies (4)
K 0345 - NFPA 101 Fire Alarm System - Testing and Maintenance: sensitivity testing of the smoke detectors had not been conducted and no documentation was available for the previous test, affecting all residents and staff.
K 0353 - NFPA 101 Sprinkler System - Maintenance and Testing: stored items in the Laundry Room were kept in excess of 18 inches within a sprinkler head; this was corrected by staff during the survey.
K 0372 - NFPA 101 Subdivision of Building Spaces - Smoke Barrier: penetrations in the firewalls (near room 313 and on 600 hall) were not properly sealed; this was corrected by staff during the survey.
K 0511 - NFPA 101 Utilities - Gas and Electric: electrical boxes in the Electrical Room were blocked by folding chairs, preventing required clearance around electrical panels; this was corrected by staff during the survey.

Inspection Report — Jun 25, 2024

Follow-Up
Date: Jun 25, 2024

Visit Reason
A health revisit was conducted via desk review to verify correction of deficiencies cited in the Complaint Investigation survey conducted on 4/25/2024.

Findings
A desk review health revisit on 06/25/2024 verified that all deficiencies cited as a result of the Complaint Investigation survey conducted on 4/25/2024 have been corrected.

Inspection Report — Apr 25, 2024

Complaint Investigation
Date: Apr 25, 2024

Visit Reason
The inspection was conducted to investigate whether the facility's Social Service Director met the required qualifications for a facility with more than 120 beds.

Complaint Details
The investigation was complaint-related, focusing on the qualifications of the Social Service Director. The complaint was substantiated as the director did not meet the required qualifications.
Findings
The facility failed to ensure that the Social Service Director had the proper qualifications, as the current director did not have a four-year degree or Social Worker degree but was working towards completing her Bachelor's degree.

Deficiencies (1)
F 0850: The facility failed to hire a qualified full-time social worker for a facility with more than 120 beds. The current Social Service Director lacked a Bachelor's degree and proper Social Worker credentials but was in the process of completing her degree.
Report Facts
Licensed beds: 178 Percentage of degree completion: 26

Employees mentioned
NameTitleContext
Social Service DirectorMentioned in relation to qualification deficiency
AdministratorProvided interview regarding Social Service Director qualifications

Inspection Report — Apr 25, 2024

Complaint Investigation
Date: Apr 25, 2024

Visit Reason
Abbreviated/Partial Extended Survey investigating complaint intake numbers GA00241524, GA00241783, GA00243142, GA00245246 and GA00245890 conducted April 23–25, 2024.

Complaint Details
Complaint intake GA00241524 was substantiated with no deficiencies cited; GA00241783, GA00245246 and GA00245890 were unsubstantiated; GA00243142 was substantiated with a deficiency cited.
Findings
The facility was cited for one deficiency for failing to ensure the Social Service Director had required qualifications for a facility licensed for over 120 beds.

Deficiencies (1)
F 0850 - Qualifications of Social Worker >120 Beds: the facility failed to ensure that the Social Service Director had the proper qualifications for a facility licensed for over 120 beds; the facility is licensed for 178 beds and the SSD had only an Associate of Arts degree and a Certificate of Completion and was still completing her Social Work degree.

Inspection Report — Nov 9, 2023

Follow-Up
Date: Nov 9, 2023

Visit Reason
Revisit survey conducted November 8-9, 2023 to verify correction of deficiencies cited during the September 28, 2023 Complaint Investigation Survey.

Findings
All deficiencies cited in the September 28, 2023 Complaint Investigation Survey were found to be corrected during the November 8-9, 2023 revisit.

Inspection Report — Sep 28, 2023

Complaint Investigation
Date: Sep 28, 2023

Visit Reason
An Abbreviated/Partial Extended Survey investigating complaints GA00232589, GA00232851, GA00232945, GA00235738, GA00236245, GA00236662, GA00236802, GA00237742, GA00239322 and GA00239444.

Complaint Details
Complaints GA00232589 and GA00239322 were substantiated with deficiencies. Complaints GA00232851, GA00232945, GA00235738, GA00236245, GA00236662, GA00236802, GA00237742, and GA00239444 were unsubstantiated with no deficiencies.
Findings
The facility was cited for 2 deficiencies: involuntary seclusion on the Memory Care Unit when a staff member placed towels/linens on residents' doors (F 0603) and failure to document witnessed destruction of fentanyl patches for one resident (F 0755).

Deficiencies (2)
F 0603 - Involuntary seclusion/abuse: staff on the Memory Care Unit placed bath linens/towels on top of resident room doors to keep residents from opening their doors; the total sample was 14 residents.
F 0755 - Fentanyl patch disposal: the facility failed to ensure used fentanyl patches for Resident #9 were destroyed in the presence of two licensed nurses and documented on the destruction form, with no documentation for patches applied 9/24/2023 and 9/27/2023.

Inspection Report — Sep 28, 2023

Complaint Investigation
Date: Sep 28, 2023

Visit Reason
The inspection was conducted following a complaint and investigation into allegations of staff-to-resident abuse involving involuntary seclusion and improper medication disposal practices at the facility.

Complaint Details
The complaint involved allegations that a CNA was using towels to keep residents confined to their rooms on the Memory Care Unit, which was confirmed by interviews, video review, and staff statements. The CNA was removed from duties and terminated. The complaint also included failure to properly destroy controlled medication patches.
Findings
The facility failed to prevent involuntary seclusion of residents on the Memory Care Unit by a CNA who placed bath linens on resident room doors to keep them closed. Additionally, the facility failed to ensure proper destruction and documentation of fentanyl patches for one resident as required by policy.

Deficiencies (2)
F 0603: The facility failed to ensure residents on the Memory Care Unit were free from involuntary seclusion when a CNA placed bath linens on top of resident room doors to keep them from opening. The CNA was found to be aggressive and hostile, and was terminated following the investigation.
F 0755: The facility failed to ensure fentanyl patches were destroyed in the presence of two licensed nurses and documented on the required form for one resident. The nurse did not document witnessed destruction due to missing in-service training.
Report Facts
Residents in Memory Care Unit: 15 Sample size: 14 Fentanyl patch application dates: 2

Employees mentioned
NameTitleContext
CNA CCCertified Nursing AssistantNamed in findings related to involuntary seclusion and abusive behavior
LPN AALicensed Practical NurseReported aggressive behavior of CNA CC and improper towel use
LPN BBLicensed Practical NurseObserved towel use on doors and reported to administration
Administrator HHAssistant AdministratorObserved towel use and confronted CNA CC
Administrator GGPrevious AdministratorNotified of abuse concerns and reported to state
Director of NursingDirector of NursingInterviewed regarding abuse and medication disposal findings
HR ManagerHuman Resources ManagerInvestigated abuse allegations and interviewed staff

Inspection Report — Apr 12, 2023

Follow-Up
Date: Apr 12, 2023

Visit Reason
Revisit survey conducted to verify correction of deficiencies cited during the February 16, 2023 Standard Survey.

Findings
All deficiencies cited as a result of the February 16, 2023 Standard Survey were found to be corrected during the April 4, 2023 revisit.

Inspection Report — Apr 6, 2023

Life Safety
Date: Apr 6, 2023

Visit Reason
Life Safety Code revisit to verify correction of previously cited LSC deficiencies.

Findings
A Life Safety Code revisit was conducted on 2023-04-06 and all previously cited LSC deficiencies were found to be corrected.

Inspection Report — Feb 16, 2023

Date: Feb 16, 2023

Visit Reason
The inspection was conducted to assess compliance with regulatory requirements related to resident care, facility environment, and specialized services at the Rehabilitation Center of South Georgia.

Findings
The facility was found deficient in maintaining clean and sanitary feeding pumps and environment, failure to apply for required Level II PASRR for a resident with mental illness, failure to implement care plans for activities of daily living including bathing, and improper storage of respiratory equipment.

Deficiencies (5)
F 0584: The facility failed to ensure feeding pumps for three residents were clean and sanitary, and failed to maintain a clean environment with scuffed walls, stained ceiling tiles, and dusty air vents.
F 0645: The facility failed to apply for a Level II PASRR for one resident with a diagnosis of Bipolar and Major Depressive Disorder, despite meeting criteria upon admission.
F 0656: The facility failed to implement a complete care plan for one resident related to activities of daily living, specifically not providing scheduled showers or baths.
F 0677: The facility failed to ensure one resident received scheduled showers and baths as required by the care plan.
F 0695: The facility failed to properly store respiratory equipment for one resident, increasing risk of respiratory infections.
Report Facts
Residents affected: 3 Residents affected: 1 Residents affected: 1 Residents affected: 1

Employees mentioned
NameTitleContext
Director of NursingInterviewed regarding feeding pump cleaning, care plan implementation, and respiratory equipment storage
AdministratorInterviewed regarding facility cleanliness and equipment expectations
Housekeeping SupervisorInterviewed regarding cleaning responsibilities
Assistant Director of NursingInterviewed regarding resident bathing documentation and care plan adherence
Behavioral Nurse PractitionerInterviewed regarding behavioral services for resident R#87
Social Services DirectorInterviewed regarding Level II PASRR completion responsibilities
Environmental Services DirectorInterviewed regarding facility environment concerns

Inspection Report — Feb 16, 2023

Annual Inspection
Date: Feb 16, 2023

Visit Reason
Standard survey conducted to assess facility compliance and to investigate Complaint Intake Number GA00230277.

Complaint Details
Complaint Intake Number GA00230277 was investigated.
Findings
The facility was cited for five deficiencies involving facility cleanliness and sanitation (feeding pumps, scuffed walls, dusty vents), failure to apply for a Level II PASRR for a resident, failures related to implementation of bathing care and shower scheduling for a resident, and improper storage of respiratory equipment (CPAP and nasal cannula).

Deficiencies (5)
F 0584 - Facility cleanliness: feeding pumps for three of four residents (R#2, R#5, R#26) had dried formula and grime on the pump, pole and base, and the facility had scuffed walls and very heavy dust build-up on ceiling vents outside rooms 104-105.
F 0645 - PASRR Level II application: the facility failed to apply for a Level II PASRR for resident R#87 who had a positive Level I PASRR and diagnoses of bipolar and major depressive disorder.
F 0656 - Plan of care implementation: the facility failed to implement the plan of care for resident R#267 related to activities of daily living, specifically not receiving a shower/bath as indicated.
F 0677 - Shower/Tub bath provision: the facility failed to ensure R#267 received scheduled showers/baths and proper documentation, with gaps in bath documentation from 12/5/2022 through 12/14/2022.
F 0695 - Respiratory equipment storage: CPAP mask and oxygen nasal cannula for resident R#62 were observed draped on bedside tables and walker handles and not properly stored when not in use.

Inspection Report — Feb 15, 2023

Life Safety
Date: Feb 15, 2023

Visit Reason
Life Safety Code survey to determine compliance with 42 CFR Subpart 483.90(a) and NFPA 101 Life Safety Code.

Findings
The facility was cited for 11 Life Safety Code deficiencies involving blocked means of egress, emergency and exit lighting testing, cooking hood suppression issues, missing ceiling tiles, fire alarm circuit identification, sprinkler system out of service and piping obstructions, electrical hazards (open boxes/wiring and power strips), inadequate fire drill timing on 2nd shift, combustible decorations on a door, and lack of generator load bank testing.

Deficiencies (11)
K 0211 - NFPA 101 Means of Egress - General: the exterior walkway in the path of egress in the 300 Back Hall was blocked by trashcans and wheelchairs.
K 0291 - NFPA 101 Emergency Lighting: the annual 90-minute test for emergency lights was not completed.
K 0293 - NFPA 101 Exit Signage: annual 90-minute testing of exit signs was not completed.
K 0324 - NFPA 101 Cooking Facilities: two deficiencies were cited on the semi-annual inspection report (corrosion on the control head and on the pull station) and cooking equipment was not positioned correctly under suppression nozzles; the citation was resolved during this survey.
K 0331 - NFPA 101 Interior Wall and Ceiling Finish: ceiling tiles were missing affecting the Kitchen and the Back 300 Utility Closet.
K 0341 - NFPA 101 Fire Alarm System - Installation: the circuit serving the fire alarm was not locked in the open position, was not identified at the fire alarm control panel, and was not clearly marked at the electrical panel.
K 0353 - NFPA 101 Sprinkler System - Maintenance and Testing: the sprinkler system was red-tagged and placed out of service, and wire was observed on the sprinkler piping in the attic.
K 0511 - NFPA 101 Utilities - Gas and Electric: power strips lying on the floor, open junction boxes, and open wiring splices were observed in areas including the Scheduling Office, PCC Office, and the attic above 300 Front Hall.
K 0712 - NFPA 101 Fire Drills: fire drills were not conducted at random times for 2nd Shift.
K 0753 - NFPA 101 Combustible Decorations: the door for the Activities Director Office was fully covered in construction paper.
K 0918 - NFPA 101 Electrical Systems - Essential Electric System Maintenance and Testing: no load bank testing has been conducted on the generator.

Inspection Report — Dec 7, 2022

Follow-Up
Date: Dec 7, 2022

Visit Reason
A revisit survey was conducted to determine whether deficiencies cited during the 10/04/2022 re-certification survey were corrected.

Findings
All deficiencies cited as a result of the 10/04/2022 re-certification survey were found to be corrected. No deficiencies were cited on this revisit conducted 12/07/2022.

Inspection Report — Nov 9, 2022

Complaint Investigation
Date: Nov 9, 2022

Visit Reason
An Abbreviated/Partial Extended Survey was conducted to investigate complaint GA00229301.

Complaint Details
Complaint GA00229301 was substantiated.
Findings
The complaint (GA00229301) was substantiated and no deficiencies were cited.

Inspection Report — Oct 4, 2022

Complaint Investigation
Date: Oct 4, 2022

Visit Reason
An Abbreviated/Partial Extended Survey was conducted to investigate complaints GA00221625, GA00221707, GA00223645, GA00225713, GA00225845, and GA00226772.

Complaint Details
Complaints GA00221625, GA00221707, and GA00223645 were unsubstantiated. Complaints GA00225713, GA00225845, and GA00226772 were substantiated with deficiencies.
Findings
The survey identified 3 deficiencies: failure to report suspected illegal drug use for Resident "A", failure to timely report an allegation of abuse for Resident "B", and failure to implement interventions to prevent side-rail related injuries for Resident "B".

Deficiencies (3)
F 0608 - Reporting of reasonable suspicion of a crime: the facility failed to report an allegation of illegal drug use to the State Survey Agency for one resident (R "A") from a total sample of eight residents.
F 0609 - Reporting of alleged violations: the facility failed to ensure an allegation of abuse was reported to the State Survey Agency in a timely manner for one resident (R "B") from a total sample of eight residents.
F 0689 - Free of accident hazards/supervision/devices: the facility failed to implement interventions in a timely manner to prevent further injury from bed side rails for one resident (R "B") from a total sample of eight residents; R "B" sustained a bruise with swelling to the top of the head on 7/6/22 after an abrasion on 7/4/22 attributed to hitting the upper assist rail.

Inspection Report — Jan 26, 2022

Complaint Investigation
Date: Jan 26, 2022

Visit Reason
An Abbreviated/Partial Extended Survey investigating complaint #GA00219461.

Complaint Details
Complaint #GA00219461 was unsubstantiated.
Findings
The complaint was unsubstantiated and no deficiencies were cited.

Inspection Report — Nov 17, 2021

Follow-Up
Date: Nov 17, 2021

Visit Reason
A Revisit survey was conducted on 11/16/2021 through 11/17/2021 to verify correction of deficiencies cited in the 9/29/2021 Complaint Investigation Survey.

Complaint Details
Complaint Intake GA00218793 was investigated and found to be unsubstantiated.
Findings
All deficiencies cited as a result of the 9/29/2021 Complaint Investigation Survey were found to be corrected. Complaint Intake GA00218793 was investigated and found to be unsubstantiated.

Inspection Report — Nov 17, 2021

Complaint Investigation
Date: Nov 17, 2021

Visit Reason
An Abbreviated/Partial Extended Survey was conducted to investigate complaint #GA00218793.

Complaint Details
Complaint GA00218793 was unsubstantiated and no regulatory violations were cited.
Findings
Complaint GA00218793 was unsubstantiated and no regulatory violations were cited.

Inspection Report — Sep 29, 2021

Complaint Investigation
Date: Sep 29, 2021

Visit Reason
Abbreviated/Partial Extended Survey investigating complaints GA00215334, GA00215460, GA00215472, and GA00216957.

Complaint Details
Complaints GA00215472 and GA00216957 were unsubstantiated; GA00215334 and GA00215460 were substantiated.
Findings
The facility was cited for 7 deficiencies involving resident rights/privacy; failure to timely report alleged violations; inadequate care planning and wound care (including weekend and pressure ulcer care); deficient ADL/perineal care; and unsecured medication carts.

Deficiencies (7)
F 0550 - Resident rights/privacy: staff failed to provide privacy by closing window blinds during perineal care for two of three residents (R#1, R#4) and treated R#4 without dignity by comparing her to another resident during care.
F 0609 - Reporting of alleged violations: facility failed to timely report alleged resident-to-resident altercations, injuries of unknown origin, and an alleged staff-to-resident allegation for four of five reports reviewed (R#1, R#10, R#12, R#13).
F 0656 - Comprehensive care plan: facility failed to develop a care plan for a surgical site for R#2 and failed to follow care plans for providing wound care on weekends for four of 13 sampled residents (R#1, R#3, R#4, R#6).
F 0677 - ADL care: facility failed to provide thorough perineal care for two of three dependent residents (R#1, R#4), requiring multiple additional wipes and leaving R#4 exposed while seeking assistance.
F 0684 - Quality of care: facility failed to follow physician orders and provide weekend wound care for two of three residents with surgical wounds (R#2, R#6), with TARs showing absence of documented treatments on multiple weekend dates.
F 0686 - Pressure ulcer treatment: facility failed to ensure wound care and treatments were provided on weekends for two of three residents with pressure ulcers (R#2, R#4), with TARs missing initials for multiple weekend dates.
F 0761 - Label/store drugs: two of four medication carts were unsecured or had nonfunctioning locks (300 Hall cart lock engaged but drawers opened; 600 Hall cart observed unlocked while nurse charted).

Inspection Report — May 27, 2021

Complaint Investigation
Date: May 27, 2021

Visit Reason
An Abbreviated/Partial Extended Survey was conducted to investigate complaint #GA00214549.

Complaint Details
Complaint #GA00214549 was unsubstantiated with no deficiencies cited.
Findings
Complaint #GA00214549 was unsubstantiated and no deficiencies were cited.

Inspection Report — Mar 10, 2021

Follow-Up
Date: Mar 10, 2021

Visit Reason
Revisit to verify corrections from the February 2, 2021 Focused Infection Control Survey.

Findings
A revisit was conducted on 2021-03-10; all deficiencies cited in the February 2, 2021 Focused Infection Control Survey were verified corrected and the facility was in substantial compliance as of 2021-02-25.

Report Facts
:

Inspection Report — Feb 2, 2021

Routine
Date: Feb 2, 2021

Visit Reason
COVID-19 focused infection control survey to assess the facility's implementation of infection prevention and control practices during a COVID-19 outbreak.

Findings
The facility was cited for failure to ensure staff used appropriate PPE and performed hand hygiene, and for not placing residents who refused COVID-19 testing on transmission-based/droplet precautions or in private rooms/COVID observation unit during an outbreak.

Deficiencies (1)
F 0880 - Infection Prevention & Control: the facility failed to ensure staff wore proper personal protective equipment and performed hand hygiene, and failed to place eight of 16 sampled residents (R#9, R#11, R#18, R#20, R#22, R#24, R#26, R#29) who refused COVID-19 testing on droplet/transmission-based precautions or in private rooms/COVID observation unit during an outbreak.

Inspection Report — Dec 29, 2020

Life Safety
Date: Dec 29, 2020

Visit Reason
A COVID-19 Focused Emergency Preparedness Survey was conducted at Rehabilitation Center of South Georgia from December 28, 2020 through December 29, 2020.

Complaint Details
Complaint GA00210392 was unsubstantiated.
Findings
The facility was found to be in compliance with 42 CFR §483.73 related to emergency preparedness and in compliance with 42 CFR §483.80 infection control; the complaint investigated (GA00210392) was unsubstantiated.

Inspection Report — Nov 30, 2020

Complaint Investigation
Date: Nov 30, 2020

Visit Reason
An Abbreviated/Partial Extended Survey was conducted to investigate complaint #GA00209849.

Complaint Details
Complaint #GA00209849 was unsubstantiated and no deficiencies were cited.
Findings
Complaint #GA00209849 was investigated and found to be unsubstantiated; no deficiencies were cited.

Inspection Report — Nov 9, 2020

Complaint Investigation
Date: Nov 9, 2020

Visit Reason
Abbreviated/Partial Extended Survey to investigate Complaint #GA00209397.

Complaint Details
Complaint #GA00209397 was unsubstantiated and no deficiencies were cited.
Findings
Complaint #GA00209397 was unsubstantiated and no deficiencies were cited.

Inspection Report — Oct 13, 2020

Life Safety
Date: Oct 13, 2020

Visit Reason
A COVID-19 Focused Emergency Preparedness Survey and a COVID-19 Focused Infection Control Survey were conducted in conjunction with a complaint survey investigating GA00207937 and GA00206520.

Complaint Details
Complaints GA00207937 and GA00206520 were unsubstantiated and no regulatory violations were cited.
Findings
The surveys were conducted October 8, 2020 through October 13, 2020; complaints GA00207937 and GA00206520 were unsubstantiated and no regulatory violations were cited.

Inspection Report — Jul 22, 2020

Life Safety
Date: Jul 22, 2020

Visit Reason
COVID-19 focused emergency preparedness and infection control surveys were conducted at Rehabilitation Center of South Georgia on July 22, 2020.

Findings
The facility was found to be in compliance with 42 CFR 483.73 (emergency preparedness) and 42 CFR 483.80 (infection control); no deficiencies were cited.

Inspection Report — May 5, 2020

Routine
Date: May 5, 2020

Visit Reason
A COVID-19 Focused Emergency Preparedness Survey was conducted by the Centers for Medicare & Medicaid Services (CMS) on May 5, 2020. A COVID-19 Focused Infection Control Survey was conducted by the Centers for Medicare & Medicaid Services (CMS) on May 5, 2020.

Findings
The facility was found to be in compliance with 42 CFR §483.73 related to E-0024 (b)(6). The facility was found to be in compliance with 42 CFR §483.80 infection control regulations and has implemented the CMS and Centers for Disease Control and Prevention (CDC) recommended practices to prepare for COVID-19.

Inspection Report — Mar 12, 2020

Follow-Up
Date: Mar 12, 2020

Visit Reason
A revisit survey was conducted on 03/12/2020 to verify corrections from the 01/24/2020 recertification survey which had a complaint survey attached.

Findings
All deficiencies cited as a result of the 01/24/2020 recertification survey with a complaint survey attached were found to be corrected on this 03/12/2020 revisit.

Inspection Report — Mar 11, 2020

Follow-Up
Date: Mar 11, 2020

Visit Reason
Follow-Up Survey conducted on 2020-03-11 by the FSCO to verify previously cited survey tags were corrected.

Findings
On 2020-03-11 a Follow-Up Survey was conducted and it was noted that all previously cited survey tags have been corrected.

Inspection Report — Jan 24, 2020

Annual Inspection
Date: Jan 24, 2020

Visit Reason
A standard survey was conducted January 21-24, 2020 with investigation of Complaint Intake Numbers GA00199499 and GA00194813.

Complaint Details
Complaint Intake Numbers GA00199499 and GA00194813 were investigated; Complaint GA00199499 was substantiated with deficiencies.
Findings
The standard survey and complaint investigation identified deficiencies in environmental cleanliness and maintenance, quality of care related to blood sugar monitoring, respiratory/oxygen therapy, resident record confidentiality, and infection prevention/laundry practices.

Deficiencies (5)
F 0584 - Safe/clean environment: the facility failed to maintain sanitary conditions with buildup of dirt, debris and spills on floors, stained walls, bulging ceiling tiles and dusty vents in multiple halls and bathrooms, and provided a wheelchair with a broken back to Resident #478.
F 0684 - Quality of care: the facility failed to follow physician orders for finger stick blood sugar monitoring for Resident #277, with the 11:30 a.m. FSBS not performed until 1:08 p.m. when the blood sugar was 25 mg/dl and Glucagon was administered.
F 0695 - Respiratory care: the facility failed to follow the physician's order for oxygen for Resident #69, observing the resident receiving 1.5–2 LPM despite an order for 3 LPM.
F 0842 - Resident records confidentiality: white boards and posted sheets at nurses' stations displayed resident names, room numbers and insurance/health information that were visible and accessible.
F 0880 - Infection control: clean resident clothing was transported in uncovered plastic containers without lids and clean items were not consistently covered, and urinals/gray buckets were stored unbagged and unlabeled in shared bathrooms (e.g., rooms 512/514, 501/502, 405/407).

Inspection Report — Jan 21, 2020

Life Safety
Date: Jan 21, 2020

Visit Reason
Life Safety Code survey and emergency preparedness program review of the facility.

Findings
During a Life Safety Code survey and emergency preparedness program review on 2020-01-21, the facility was cited for three deficiencies related to emergency lighting, sprinkler system maintenance, and smoke barrier/fire wall penetrations. The emergency preparedness program review was found to be in substantial compliance.

Deficiencies (3)
K 0281 - Illumination of Means of Egress: emergency lighting in the entrance hallway, activity hallway, hallway 600 and showers rooms A and B failed to illuminate when tested during a tour on 01-21-20.
K 0353 - Sprinkler System - Maintenance and Testing: sprinkler heads were rusted in the conference room and Hallway 200 bathroom, observed during a tour on 01-21-20.
K 0372 - Subdivision of Building Spaces - Smoke Barrier: the fire wall was penetrated in Hallway 600, observed during a tour on 01-21-20.

Inspection Report — Jan 7, 2019

Complaint Investigation
Date: Jan 7, 2019

Visit Reason
An abbreviated/Partial Extended Survey was conducted to investigate complaint GA#00193863.

Complaint Details
Complaint GA#00193863 was unsubstantiated with no deficiencies cited.
Findings
The complaint was unsubstantiated, with no deficiencies cited.

Inspection Report — Oct 15, 2018

Follow-Up
Date: Oct 15, 2018

Visit Reason
A revisit survey was conducted in conjunction with an abbreviated/partial survey to investigate complaints GA00191470 and GA00191953.

Complaint Details
Complaints GA00191470 and GA00191953 were investigated; no recommendation for citations.
Findings
The revisit and abbreviated/partial survey revealed the facility was not in substantial compliance with Medicare/Medicaid regulations at 42 CFR Part 483, Subpart B, with no recommendation for citations.

Inspection Report — Oct 15, 2018

Follow-Up
Date: Oct 15, 2018

Visit Reason
A revisit survey was conducted in conjunction with an abbreviated/partial survey to investigate complaints GA00191470 and GA00191953.

Complaint Details
Complaints GA00191470 and GA00191953 were investigated.
Findings
The revisit and abbreviated partial survey revealed that the facility was not in substantial compliance with Medicare/Medicaid regulations at 42 C.F.R. Part 483, Subpart B, with no recommendation for citations. The facility's census on October 11, 2018 was 142 residents.

Inspection Report — Sep 27, 2018

Follow-Up
Date: Sep 27, 2018

Visit Reason
A follow-up survey was conducted by the FSCO on 2018-09-27 to verify correction of previously cited deficiencies.

Findings
A follow-up survey on 2018-09-27 found that all previously cited survey tags had been corrected.

Report Facts
:

Inspection Report — Aug 9, 2018

Annual Inspection
Date: Aug 9, 2018

Visit Reason
A standard survey was conducted at Rehabilitation Center of South Georgia - Tifton from August 6 - August 9, 2018.

Findings
The survey cited four deficiencies involving care planning, fall management, and mental/psychosocial treatment: failures to fully develop comprehensive care plans related to mood and behaviors for one resident (R#134), failures to timely review/revise a fall care plan and complete therapy screens after falls for one resident (R#66), failure to conduct root cause analysis of falls leading to a hip fracture (R#66), and failure to provide treatment/services and psychiatric referral for a resident displaying depressive symptoms (R#134).

Deficiencies (4)
F 0656 - Develop/Implement Comprehensive Care Plan: the facility failed to fully develop comprehensive care plans related to mood and behaviors for one resident (R#134) of 49 sampled residents.
F 0657 - Care Plan Timing and Revision: the facility failed to review and/or revise the fall care plan for one resident (R#66) after multiple falls and did not document therapy screens as indicated.
F 0689 - Free of Accident Hazards/Supervision/Devices: the facility failed to conduct a root cause analysis to determine the cause of R#66's falls and failed to ensure fall interventions were effective; R#66 sustained a left hip fracture after a fall on 5/19/18.
F 0742 - Treatment/Services Mental/Psychosocial Concerns: the facility failed to provide appropriate treatment and services for one resident (R#134) who displayed symptoms of major depressive disorder and repeatedly voiced wanting to die, including lack of psychiatric referral and inconsistent monitoring of antidepressant therapy.

Inspection Report — Aug 6, 2018

Life Safety
Date: Aug 6, 2018

Visit Reason
Life Safety Code survey to determine compliance with 42 CFR Subpart 483.70(a) and NFPA 101.

Findings
The facility was cited for 10 life-safety deficiencies involving emergency lighting, hazardous area doors, kitchen hood cleanliness, fire alarm testing, sprinkler piping, corridor doors, smoke barrier penetrations, electrical hazards, and oxygen cylinder storage/handling.

Deficiencies (10)
K 0291 - Emergency Lighting: the emergency light at the 500 hall exterior exit door was not working.
K 0321 - Hazardous Areas - Enclosure: Central Storage at the central supply door, Wing #1 medicine storage door, Wing #1 oxygen storage door, the laundry door, and the dietary storage door did not have proper self-closing devices or did not close and latch.
K 0324 - Cooking Facilities: the kitchen exhaust duct was not properly cleaned and had heavy residue of grease.
K 0345 - Fire Alarm System - Testing and Maintenance: the annual fire alarm inspection report showed three smoke detectors located in the clean linen, dayroom, and MDS department had not been tested.
K 0353 - Sprinkler System - Maintenance and Testing: sprinkler piping was supporting wiring, water pipes, and electric conduit in multiple ceiling locations including above Rooms 313, 409, 204, 203 and the corridor by Room 409.
K 0363 - Corridor - Doors: the dietary kitchen doors on Wing #1 and Wing #2 were not latching because there was not a keeper in the lockset.
K 0372 - Subdivision of Building Spaces - Smoke Barrier: multiple penetrations in smoke barriers (above the 600 shower, Room 602, corridor by Room 312, Room 407, and Room 409) were not properly sealed with a listed fire stop system.
K 0511 - Utilities - Gas and Electric: observed electrical hazards included uncovered junction boxes in the corridor above Room 312, an improperly mounted strip adapter and an unapproved cube adapter in the Social Services Director's office, and two unapproved extension cords used as fixed wiring in the Staff Development office.
K 0923 - Gas Equipment - Cylinder and Container Storage: Wing #1 oxygen storage room did not separate full and empty oxygen cylinders.
K 0929 - Gas Equipment - Precautions for Handling Oxygen: oxygen cylinders were not properly secured in a rack or cylinder storage cart to prevent them from falling over and being damaged.

Inspection Report — Apr 24, 2018

Follow-Up
Date: Apr 24, 2018

Visit Reason
Revisit survey to verify correction of deficiencies cited in the February 23, 2018 Complaint Survey.

Complaint Details
All deficiencies cited as a result of the February 23, 2018 Complaint Survey were found to be corrected.
Findings
All deficiencies cited as a result of the February 23, 2018 Complaint Survey were found to be corrected on April 24, 2018.

Inspection Report — Feb 23, 2018

Complaint Investigation
Date: Feb 23, 2018

Visit Reason
Abbreviated/Partial Extended survey investigating complaint GA00185574.

Complaint Details
Complaint GA00185574 was unsubstantiated but with deficiencies.
Findings
The State report cited the facility for failing to revise care plans to reflect the actual presence of a pressure sore for two of three sampled residents.

Deficiencies (2)
F 0657 - Care Plan Timing and Revision: the facility failed to revise the care plan to reflect the actual presence of a pressure sore for two (#2 and #3) of three sampled residents.
F 0686 - Treatment/ Svcs to Prevent/ Heal Pressure Ulcer: the facility failed to accurately stage pressure sores for two residents (#2 and #3), with wounds observed as 100 percent black eschar and unstageable despite prior documentation of Stage II.

Inspection Report — Nov 9, 2017

Follow-Up
Date: Nov 9, 2017

Visit Reason
A revisit survey was conducted on 11/9/17.

Findings
All deficiencies cited as a result of the 8/24/17 Standard Survey were found to be corrected; no deficiencies were cited as a result of the 11/9/17 revisit.

Inspection Report — Nov 6, 2017

Follow-Up
Date: Nov 6, 2017

Visit Reason
Follow-Up Survey to determine whether previously cited survey tags had been corrected.

Findings
All previously cited survey tags were verified as corrected on 2017-11-06; no new deficiencies were cited as a result of this follow-up survey.

Inspection Report — Aug 24, 2017

Annual Inspection
Date: Aug 24, 2017

Visit Reason
A standard survey was conducted at Rehabilitation Center of South Georgia from 8/21/17 through 8/24/17 to assess compliance with Medicare/Medicaid long term care facility regulations.

Findings
The facility was cited for improper disposal and storage of garbage and cardboard and for failure to maintain an effective pest control program, with live roaches observed in the kitchen and inadequate pest control documentation and housekeeping.

Deficiencies (2)
F 0372 - Dispose garbage & refuse properly: observations of two bags of trash outside the kitchen with flies, flattened cardboard with standing water and large unflattened cardboard piled next to dumpsters spilling out of a broken enclosure.
F 0469 - Maintains effective pest control program: live roaches were observed in the kitchen and dry storage on multiple dates and pest control records showed live roaches from January to June 2017 with limited vendor recommendations and lack of documented prevention measures.

Inspection Report — Aug 22, 2017

Life Safety
Date: Aug 22, 2017

Visit Reason
Life Safety Code survey to determine compliance with 42 CFR Subpart 483.70(a) and NFPA 101 (2012).

Findings
The facility was cited for multiple life safety deficiencies including obstructed means of egress, improper locking devices on doors, lack of approved guards and emergency lighting, inadequate exit signage testing, sprinkler and sprinkler maintenance deficiencies, fire alarm sensitivity testing omissions, improperly mounted fire extinguishers, and numerous electrical hazards.

Deficiencies (15)
K 0211 - NFPA 101 Means of Egress - General: observation and staff interview determined the facility failed to maintain exits free from obstructions, including the 600 hall corridor blocked by equipment storage on both sides, the 600 hall exit discharge ramp blocked by furniture, and the 600 hall exit discharge door covered with fabric blocking visibility.
K 0222 - NFPA 101 Egress Doors: observation and staff interview determined the facility failed to provide approved locking arrangements and doors that operate with one action of the hand; findings included restroom doors with latches and deadbolts, Room 102 having a latch, deadbolt and slide bolt, and slide bolts present on kitchen and lobby doors.
K 0227 - NFPA 101 Ramps and Other Exits: observation and staff interview determined the facility failed to provide approved guards on 4 of 4 landings and ramps greater than 30 inches above grade; guards did not have intermediate rails to prevent a 4-inch sphere at the 500 hall exit landing/ramp, main office porch/ramp, 20th street porch/ramp, and 600 hall exit landing/ramp.
K 0291 - NFPA 101 Emergency Lighting: observation and staff interview determined the facility failed to provide emergency lighting throughout the facility, with missing emergency lighting noted at the 20th street exit discharge porch and ramp, 600 hall exit discharge landing and ramp, 3 of 3 exterior enclosed courtyards, East 300 hall, Wing 2 exterior porch/ramp, day room by dining room, and the assisted dining room.
K 0293 - NFPA 101 Exit Signage: observation, record review and staff interview determined the facility failed to ensure annual testing on exit signs and failed to maintain adequate exit signs; findings included no 90-minute annual testing for exit signs, an unapproved exit sign at cross corridor doors by Room 300, an unapproved exit sign at Room 407, and an exit sign at the Therapy office not working in emergency mode.
K 0321 - NFPA 101 Hazardous Areas - Enclosure: observation and staff interview determined the facility failed to separate hazardous areas with smoke resistant partitions and to provide required self-closing devices; findings included a central storage door with an unapproved door hold device, therapy storage door without a self-closing device with latch taped open, dining room storage without a self-closing device, staff dining used for storage without a self-closing device, and kitchen dry storage/pantry without a self-closing device.
K 0324 - NFPA 101 Cooking Facilities: observation, record review and staff interview determined the facility failed to ensure adequate cleaning of the kitchen exhaust hood and documentation that all components of the exhaust system (hoods, grease filters, ducts, fans) are cleaned frequently to bare metal.
K 0345 - NFPA 101 Fire Alarm System - Testing and Maintenance: review of facility records and staff interview determined the facility failed to properly test and maintain the fire alarm system, with 0 of 57 smoke detectors provided with sensitivity testing.
K 0351 - NFPA 101 Sprinkler System - Installation: observation, record review and staff interview determined the facility failed to ensure sprinkler protection throughout the facility, with the 600 shower storage room and 300B shower storage room not protected by the sprinkler system.
K 0353 - NFPA 101 Sprinkler System - Maintenance and Testing: observation and staff interview determined the facility failed to ensure access to the fire department connection and to maintain correct clearance to sprinkler heads, with the fire department connection concealed by flowers, shrubs and trees and 18 inches not maintained between a sprinkler deflector and the top of storage in Central Supply storage room.
K 0355 - NFPA 101 Portable Fire Extinguishers: observation and staff interview determined the facility failed to ensure 3 of 25 portable fire extinguishers were correctly mounted; extinguishers at the residence smoking courtyard, dietary kitchen, and kitchen were mounted around 70 inches above the floor to the operable handle.
K 0363 - NFPA 101 Corridor - Doors: observation and staff interview determined the facility failed to provide corridor doors that close and latch resisting the passage of smoke; doors would not close and latch or had unapproved hold open devices in areas including the patient care coordinator's office, Room 602, Room 611, Room 315, Room 108, the dining room, and the assisted dining room.
K 0372 - NFPA 101 Subdivision of Building Spaces - Smoke Barrier: observation and staff interview determined the facility failed to ensure 1/2-hour fire rated smoke barriers were properly maintained, with multiple electrical conduit, sprinkler piping and HVAC penetrations observed in smoke barriers that were not properly sealed or protected in the 600, 300, 400 (two locations), 200, 500, 300 (additional), and 100 hall smoke barriers.
K 0511 - NFPA 101 Utilities - Gas and Electric: observation and staff interview determined the facility failed to maintain electrical systems in compliance with NFPA 70, with unapproved use of multi-plug adapters observed in numerous rooms (examples: Room 504, 20th Street porch exterior, Patient Care Coordinator Office 2B, Quality Assurance office, Memory Care dayroom, Room 308, Room 203, Room 101, Room 114, Room 401, Room 403, Room 405, Room 406, dining room, activity office), surge protectors not properly mounted off the floor in Central Supply office, Environmental Service office and Administrator's office, exposed wiring not secured in a junction box in Wing 2 medical room, open junction boxes without coverplates in therapy exterior wall, laundry wall receptacle and activity office, and breakers not labeled in 4 of 8 panel boxes.
K 0920 - NFPA 101 Electrical Equipment - Power Cords and Extension Cords: observation, record review and staff interview determined the facility failed to ensure proper use of electrical extension cords, with an extension cord in Room 210 used as permanent wiring and a surge protector in use for personal items and not mounted in Room 502.

Viewing