Inspection Reports for
Gibson Health and Rehabilitation
434 BEALL SPRINGS ROAD, GIBSON, GA, 30810
Back to Facility Profile8 Reports
Inspection Report — Apr 23, 2025
Date: Apr 23, 2025
Visit Reason
The document is a Statement of Deficiencies and Plan of Correction for Gibson Health and Rehabilitation, indicating a regulatory inspection was conducted.
Findings
The report contains initial comments but does not provide specific findings or deficiencies in the extracted text or image.
Inspection Report — Feb 27, 2025
Annual Inspection
Date: Feb 27, 2025
Visit Reason
The inspection was conducted as a State Licensure survey to determine compliance with the State Long Term Care Requirements at Gibson Health and Rehabilitation.
Findings
The facility failed to develop and implement a comprehensive person-centered care plan addressing catheter care and treatment for one resident with an indwelling catheter, increasing the risk of infections. Interviews revealed lack of knowledge and documentation regarding catheter care.
Deficiencies (1)
Failure to develop and implement a comprehensive person-centered care plan addressing catheter care and treatment for one resident with an indwelling catheter.
Report Facts
Date of last catheter care documentation: Sep 19, 2024
Catheter change frequency: 30
Employees mentioned
| Name | Title | Context |
|---|---|---|
| FF | Certified Nursing Assistant | Interviewed regarding catheter care knowledge |
| CC | Licensed Practical Nurse | Interviewed regarding catheter care policy and documentation |
| Director of Nursing | Director of Nursing | Confirmed lack of catheter care documentation |
Inspection Report — Aug 3, 2023
Original Licensing
Date: Aug 3, 2023
Visit Reason
A State Licensure survey was conducted at Gibson Health and Rehabilitation from August 1, 2023 through August 3, 2023 to assess compliance with state health regulations.
Findings
The survey revealed that there were no State Health deficiencies cited during the inspection period.
Inspection Report — Feb 3, 2022
Routine
Date: Feb 3, 2022
Visit Reason
The inspection was conducted to assess compliance with nursing care plans and immunization policies at Gibson Health and Rehabilitation.
Findings
The facility failed to implement the comprehensive care plan for catheter tubing placement for one resident and failed to provide evidence that two residents were offered the Pneumococcal vaccine as required.
Deficiencies (2)
Failure to implement the comprehensive care plan related to catheter tubing placement for one resident (R#20), with catheter tubing improperly positioned hanging on the side rail without a privacy bag.
Failure to provide evidence that residents R#20 and R#36 were offered the Pneumococcal vaccine as required by facility policy and regulations.
Report Facts
Resident care plans reviewed: 12
Residents sampled for immunizations: 5
Residents not offered Pneumococcal vaccine: 2
Employees mentioned
| Name | Title | Context |
|---|---|---|
| Licensed Practical Nurse (LPN) AA | Confirmed catheter tubing placement issue for resident R#20 | |
| Director of Nursing (DON) | Confirmed expectation for nursing staff to follow care plans and discussed consent issues for Pneumococcal vaccine | |
| Assistant Director of Nursing (ADON) | Discussed consent and vaccine administration issues for residents R#20 and R#36 | |
| Infection Control Preventionist (ICP) | Responsible for obtaining consent for Pneumococcal vaccine but was out with COVID during survey |
Inspection Report — Sep 26, 2019
Routine
Date: Sep 26, 2019
Visit Reason
State of GA Inspection Report.
Findings
The facility failed to assure that physician's orders were followed related to diuretic drug use for one resident (R) (#13) of 33 sampled residents.
Deficiencies (1)
N 1018 - Medical, Dental and Nursing Care: the facility failed to assure that physician's orders were followed related to diuretic drug use for one resident (R) (#13) of 33 sampled residents.
Inspection Report — Jun 30, 2017
Annual Inspection
Date: Jun 30, 2017
Visit Reason
Standard survey with complaint investigation (Complaint Intake Number GA00170061) of Gibson Health and Rehabilitation.
Complaint Details
Complaint Intake Number GA00170061 was investigated in conjunction with this standard survey.
Findings
The survey found unsafe hot water temperatures in resident bathrooms and common showers across multiple halls; the facility implemented corrective actions including locking showers, hourly temperature monitoring, plumber intervention, and ordering system upgrades.
Deficiencies (1)
N 1861 - Temperature controls (Physical Plant Standards): hot water for personal uses exceeded 110°F; corrective actions documented include locks on common bathrooms, continuous temperature logs showing readings later between 101° to 109°F, hourly monitoring, plumber correction and ordering upgraded water equipment.
Report — June 2, 2026
June 2, 2026
Report — October 27, 2025
October 27, 2025
31 CMS Surveys
Inspection Report — Apr 23, 2025
Follow-Up
Date: Apr 23, 2025
Visit Reason
Health revisit conducted to verify correction of deficiencies cited in the 2/27/2025 Recertification Survey.
Findings
A Health Revisit survey was conducted on 04/23/2025 and all deficiencies cited as a result of the 2/27/2025 Recertification Survey were found to be corrected.
Inspection Report — Apr 15, 2025
Follow-Up
Date: Apr 15, 2025
Visit Reason
A Life Safety Code revisit/follow-up survey was conducted to verify correction of previously cited deficiencies.
Findings
A Life Safety Code revisit on 2025-04-15 found all previously cited LSC deficiencies had been corrected.
Inspection Report — Feb 27, 2025
Annual Inspection
Date: Feb 27, 2025
Visit Reason
Recertification survey conducted February 25-27, 2025 to assess compliance with Medicare/Medicaid regulations for long term care facilities.
Findings
The facility was cited for three deficiencies: two related to catheter care and comprehensive care planning for Resident R318, and one related to failure to prime an insulin pen for Resident R368 during medication administration.
Deficiencies (3)
F 0656 - Comprehensive care plan: the facility failed to develop and implement a comprehensive person-centered care plan that addressed catheter care and treatment for one of one resident reviewed (R318) with an indwelling catheter.
F 0658 - Insulin pen priming: LPN AA administered four units of insulin to R368 without priming the insulin pen, failing to remove air and ensure an accurate insulin dose.
F 0684 - Catheter care: the facility failed to ensure R318 received catheter care per policy, with no orders addressing catheter care every shift and lack of documentation for catheter care in October, November, and December 2024.
Inspection Report — Feb 27, 2025
Life Safety
Date: Feb 27, 2025
Visit Reason
During a Life Safety Code Survey conducted on 02/27/2025 to determine compliance with the requirements for participation in Medicare/Medicaid at 42 CFR Subpart 483.90(a) and NFPA 101 Life Safety Code 2012.
Findings
The facility was cited for 3 Life Safety Code deficiencies: corroded and yellow-tagged sprinkler system components, unsealed fire wall penetrations on B-hall, and electrical hazards including an open J-box and powerstrips on the floor.
Deficiencies (3)
K 0353 - NFPA 101 Sprinkler System - Maintenance and Testing: corroded sprinkler heads were observed in the kitchen and cooler and the sprinkler system was yellow tagged for repairs.
K 0372 - NFPA 101 Subdivision of Building Spaces - Smoke Barrier: a penetration in the fire wall on B-hall was not sealed properly.
K 0511 - NFPA 101 Utilities - Gas and Electric: an open J-box exposing wires was observed in the riser room and powerstrips were observed on the floor in the front offices.
Inspection Report — Jul 8, 2024
Complaint Investigation
Date: Jul 8, 2024
Visit Reason
An Abbreviated/Partial Extended Survey was conducted to investigate complaint GA00248138.
Complaint Details
Complaint GA00248138 was substantiated with no deficiencies cited.
Findings
Complaint GA00248138 was substantiated with no deficiencies cited as a result of this survey.
Inspection Report — Oct 13, 2023
Follow-Up
Date: Oct 13, 2023
Visit Reason
A Follow-Up Desk Review was conducted to verify correction of previously cited deficiencies.
Findings
The Follow-Up Desk Review noted that all previously cited survey tags have been corrected on 9/15/2023.
Inspection Report — Oct 4, 2023
Follow-Up
Date: Oct 4, 2023
Visit Reason
A revisit survey was conducted on October 4, 2023 to verify correction of deficiencies cited in the September 12, 2023 Federal Focus Survey.
Findings
All deficiencies cited as a result of the September 12, 2023 Federal Focus Survey were found to be corrected during the October 4, 2023 revisit. The facility had a census of 56.
Inspection Report — Oct 2, 2023
Follow-Up
Date: Oct 2, 2023
Visit Reason
On 10/02/2023 a Follow-Up Survey was conducted by this FSCO to determine whether previously cited survey tags had been corrected.
Findings
On 10/02/2023 a Follow-Up Survey was conducted and it was noted that all previously cited survey tags have been corrected.
Inspection Report — Sep 14, 2023
Life Safety
Date: Sep 14, 2023
Visit Reason
Unannounced Emergency Preparedness and Life Safety Code Federal Monitoring Survey conducted on 9/14/2023 following a State Agency survey on 8/3/2023.
Findings
The facility was cited for 2 Life Safety Code deficiencies: missing automatic sprinklers in the Therapy Building attic and a corridor/linen room door that was not positive latching.
Deficiencies (2)
K 0351 - NFPA 101 Sprinkler System - Installation: sprinklers were not installed in the attic of the Therapy Building, the roof is constructed of untreated wood, and residents received therapy in the building.
K 0363 - NFPA 101 Corridor - Doors: the door to C Hall Linen Room was not positive latching due to a key code dead bolt lock installed on the door.
Inspection Report — Sep 12, 2023
Monitoring
Date: Sep 12, 2023
Visit Reason
A Federal Monitoring Focus Concern Survey (FCS) was conducted at Gibson Health and Rehabilitation on September 11-12, 2023 to assess compliance with Medicare/Medicaid regulations; an Immediate Jeopardy and Substandard Quality of Care were identified related to unsecured toxic chemicals.
Findings
One federal deficiency (F 0689) was cited for failure to ensure two housekeeping utility closets were locked and cleaning supplies stored to prevent access and exposure to toxic chemicals, placing five of 14 residents who wandered independently and had severe cognitive impairment at risk.
Deficiencies (1)
F 0689 - Accident hazards: the facility failed to ensure two housekeeping utility closets were locked and the cleaning supplies were stored to prevent access and exposure to toxic chemicals for five of 14 residents who wandered independently and had severely impaired cognition (Residents #s 1, 54, 14, 32, and 24).
Inspection Report — Aug 3, 2023
Annual Inspection
Date: Aug 3, 2023
Visit Reason
A standard survey was conducted at Gibson Health and Rehab from August 1, 2023 through August 3, 2023 to assess compliance with Medicare/Medicaid health regulations.
Findings
The standard survey found the facility in compliance with the Health portion of the Medicare/Medicaid regulations; no health deficiencies were cited.
Inspection Report — Aug 3, 2023
Life Safety
Date: Aug 3, 2023
Visit Reason
Life Safety Code survey and Emergency Preparedness Program review to evaluate the facility's compliance with NFPA 101 and 42 CFR Subpart 483.70(a).
Findings
The facility was cited for deficient emergency lighting when several emergency lights failed to operate during testing, potentially placing 15 residents at risk.
Deficiencies (1)
K 0291 - Emergency Lighting: the emergency lighting unit in the kitchen over the prep table and two units on the 200 Hall did not operate when the test button was pushed during a tour on 08/03/2023, which could place 15 residents at risk.
Inspection Report — Jun 27, 2023
Complaint Investigation
Date: Jun 27, 2023
Visit Reason
An Abbreviated/Partial Extended Survey was conducted to investigate complaint #GA00232595.
Complaint Details
Complaint #GA00232595 was unsubstantiated and no regulatory violations were cited.
Findings
Complaint #GA00232595 was unsubstantiated and no regulatory violations were cited.
Inspection Report — Apr 12, 2022
Follow-Up
Date: Apr 12, 2022
Visit Reason
A revisit survey was conducted on 4/12/2022 to verify correction of deficiencies cited as a result of 2/03/2022 recertification survey.
Findings
All deficiencies cited as a result of 2/03/2022 recertification survey were found to be corrected. The facility had a census of 54.
Inspection Report — Feb 3, 2022
Annual Inspection
Date: Feb 3, 2022
Visit Reason
Standard survey of the facility to determine compliance with Medicare/Medicaid regulations.
Findings
The facility was cited for 5 federal deficiencies involving resident abuse, failure to implement a care plan for catheter tubing placement, missed wound treatments for pressure ulcers, improper Foley catheter positioning/privacy bag use, and failure to document offering pneumococcal vaccination to residents.
Deficiencies (5)
F 0600 - Free from Abuse and Neglect: the facility failed to ensure residents were protected from verbal abuse; one resident (R#154) reported a CNA entering her room using a loud voiced tone and speaking inappropriately, the incident was investigated, the CNA was suspended and later terminated.
F 0656 - Develop/Implement Comprehensive Care Plan: the facility failed to implement the comprehensive care plan related to catheter tubing placement for Resident R#20; the Foley catheter was observed hanging on the resident's side rail without a privacy bag.
F 0686 - Treatment/Services to Prevent/Heal Pressure Ulcer: the facility failed to provide treatments as ordered for two residents (R#10 and R#41), including missed dressing changes (e.g., R#10 toe dressing dated 1/25/22 not changed) and R#41 sacral dressing soiled with a date of 1/29/22 and treatments not documented on multiple dates.
F 0690 - Bowel/Bladder Incontinence, Catheter, UTI: the facility failed to ensure an indwelling Foley catheter was placed in a privacy bag and positioned properly for Resident R#20; observations on 2/1/22 and 2/3/22 found cloudy urine with sediment and the catheter hanging on the side rail without a privacy bag.
F 0883 - Influenza and Pneumococcal Immunizations: the facility failed to provide evidence that residents were offered the pneumococcal vaccine for two residents (R#20 and R#36) and lacked documented consents, with MDS and facility vaccine reports indicating the vaccine had not been offered.
Inspection Report — Feb 2, 2022
Life Safety
Date: Feb 2, 2022
Visit Reason
Review of the Emergency Preparedness Program and a Life Safety Code survey were conducted for Gibson Health & Rehabilitation on February 2, 2022.
Findings
The Emergency Preparedness Program was in substantial compliance with LTC 42 CFR § 483.73, and the facility was found in substantial compliance with Life Safety Code requirements.
Inspection Report — Jul 28, 2021
Complaint Investigation
Date: Jul 28, 2021
Visit Reason
Abbreviated/Partial Extended Survey initiated to investigate complaints #GA00213443, #GA00213775 and #GA00215971.
Complaint Details
Complaints #GA00213443, #GA00213775 and #GA00215971 were unsubstantiated with no deficiencies cited.
Findings
Complaints #GA00213443, #GA00213775 and #GA00215971 were unsubstantiated with no deficiencies cited.
Inspection Report — Dec 16, 2020
Life Safety
Date: Dec 16, 2020
Visit Reason
COVID-19 Focused Emergency Preparedness and COVID-19 Focused Infection Control surveys were conducted on December 16, 2020 by Healthcare Management Solutions, LLC on behalf of the Georgia Department of Community Health.
Findings
The facility was found to be in compliance with 42 CFR §483.73 related to emergency preparedness and with 42 CFR §483.80 infection control regulations following the COVID-19 focused surveys.
Inspection Report — Jun 16, 2020
Routine
Date: Jun 16, 2020
Visit Reason
COVID-19 Focused Emergency Preparedness and Focused Infection Control Survey conducted on June 16, 2020 to assess the facility's preparedness and infection control practices related to COVID-19.
Findings
The facility was found to be in compliance with emergency preparedness (42 CFR §483.73) and infection control (42 CFR §483.80); no deficiencies were cited.
Inspection Report — Nov 13, 2019
Follow-Up
Date: Nov 13, 2019
Visit Reason
A revisit survey was conducted on 11/13/19.
Findings
A revisit survey was conducted on 11/13/19. All deficiencies cited as a result of 9/26/19 Standard Survey were found to be corrected.
Inspection Report — Nov 13, 2019
Follow-Up
Date: Nov 13, 2019
Visit Reason
A Follow-Up Survey was conducted on 11/13/2019 to verify that previously cited survey tags had been corrected.
Findings
All previously cited survey tags were noted as corrected during the follow-up survey on 11/13/2019.
Inspection Report — Sep 26, 2019
Routine
Date: Sep 26, 2019
Visit Reason
State of GA Inspection Report.
Findings
The facility failed to assure that physician's orders were followed related to diuretic drug use for one resident (R) (#13) of 33 sampled residents.
Deficiencies (2)
F 0684 - Quality of care: the facility failed to assure that physician's orders were followed related to diuretic drug use for one resident (R) (#13) of 33 sampled residents.
F 0812 - Food safety: two items (chopped carrots and egg noodles) on the steam table were 120 degrees F, below the required 135 degrees F, with the potential to affect 73 residents receiving an oral diet.
Inspection Report — Sep 23, 2019
Life Safety
Date: Sep 23, 2019
Visit Reason
Life Safety Code Survey conducted on 09/23/2019 to determine compliance with 42 CFR Subpart 483.70(a) and the NFPA 101 Life Safety Code 2012 edition.
Findings
The facility was cited for 6 life-safety deficiencies involving sprinkler system protection and maintenance, corroded sprinkler heads, corridor doors that do not close or latch properly, a cross-corridor rated door that does not close fully, an open electrical connection without a junction box cover, and a space heater in the MDS Office that does not meet requirements.
Deficiencies (6)
K 0351 - NFPA 101 Sprinkler System - Installation: fire sprinkler piping located in the Outside Can Wash Room is not protected from freezing.
K 0353 - NFPA 101 Sprinkler System - Maintenance and Testing: a corroded fire sprinkler head was observed on the Kitchen Loading Dock.
K 0363 - NFPA 101 Corridor - Doors: doors protecting corridor openings (Electrical Room, Mechanical Room 4, Pantry) do not close fully and latch.
K 0374 - NFPA 101 Subdivision of Building Spaces - Smoke Barrier: the Cross Corridor C Hall Right Door (rated corridor door) does not close fully.
K 0511 - NFPA 101 Utilities - Gas and Electric: an open electrical connection was observed behind dryer #2 that is not in the required junction box with a cover.
K 0781 - NFPA 101 Portable Space Heaters: a space heater was located in the MDS Office that does not meet the code requirements for portable space heaters.
Inspection Report — Jul 18, 2018
Follow-Up
Date: Jul 18, 2018
Visit Reason
Follow-up survey to verify that previously cited survey tags were corrected.
Findings
On 2018-07-18 a follow-up survey was conducted and all previously cited survey tags were found to be corrected.
Inspection Report — Jun 14, 2018
Annual Inspection
Date: Jun 14, 2018
Visit Reason
A standard survey was conducted at Gibson Health and Rehab from 6/11/18 through 6/14/18.
Findings
The standard survey revealed the facility was in substantial compliance with Medicare/Medicaid regulations at 42 Code of Federal Regulations (C.F.R.) Part 43, Subpart B; no deficiencies were cited.
Inspection Report — Jun 12, 2018
Life Safety
Date: Jun 12, 2018
Visit Reason
Life Safety Code survey and Emergency Preparedness plan review conducted on 06/12/2018.
Findings
The Emergency Preparedness plan was found to be in substantial compliance on review, but the facility was cited for five Life Safety Code deficiencies. Deficiencies involved emergency lighting, emergency lighting/fire alarm components, exit signage lighting, electrical/utilities issues, and improper oxygen cylinder storage.
Deficiencies (5)
K 0281 - Illumination of Means of Egress: the facility failed to maintain emergency lighting; the emergency light for egress from the building outside Hall A patio doors did not work when manually manipulated.
K 0291 - Emergency Lighting: the facility failed to maintain the fire alarm and/or its components; the batteries in the Physical Therapy building were not installed with manufacturer's date, only the date of install was discovered.
K 0293 - Exit Signage: the exit sign on C hall at the fire doors was not operative on DC power when manually manipulated.
K 0511 - Utilities - Gas and Electric: an extension cord was in permanent use in Physical Therapy and power strips were found on floors under desks in PT and the MDS office.
K 0923 - Gas Equipment - Cylinder and Container Storage: 02 cylinders in the storage area were mixed empty and full together.
Inspection Report — Feb 6, 2018
Complaint Investigation
Date: Feb 6, 2018
Visit Reason
An Abbreviated/Partial Extended Survey was conducted to investigate complaint GA00184816.
Complaint Details
Complaint GA00184816 was unsubstantiated.
Findings
The complaint GA00184816 was investigated and found to be unsubstantiated; no deficiencies were cited.
Inspection Report — Aug 21, 2017
Follow-Up
Date: Aug 21, 2017
Visit Reason
A Follow-Up Survey was conducted by the FSCO to determine whether previously cited survey tags had been corrected.
Findings
The follow-up survey conducted on 2017-08-21 found that all previously cited survey tags had been corrected.
Inspection Report — Aug 18, 2017
Follow-Up
Date: Aug 18, 2017
Visit Reason
A revisit survey was conducted to verify correction of deficiencies cited in the June 30, 2017 Recertification Survey.
Findings
All deficiencies cited as a result of the June 30, 2017 Recertification Survey were found to be corrected.
Inspection Report — Jun 30, 2017
Annual Inspection
Date: Jun 30, 2017
Visit Reason
Standard survey with complaint investigation (Complaint Intake Number GA00170061) of Gibson Health and Rehabilitation.
Complaint Details
Complaint Intake Number GA00170061 was investigated in conjunction with this standard survey.
Findings
The survey found unsafe hot water temperatures in resident bathrooms and common showers across multiple halls; the facility implemented corrective actions including locking showers, hourly temperature monitoring, plumber intervention, and ordering system upgrades.
Deficiencies (2)
F 0323 - Free of accident hazards/supervision/devices: unsafe hot water temperatures were identified on A, B and C halls with temperatures measured as high as 139.5°F, staff did not continuously monitor resident bathrooms, and locks were placed on shower rooms with hourly temperature checks implemented.
F 0490 - Effective administration/resident well-being: the facility failed to ensure safe hot water temperatures with temperature logs and interviews confirming temperatures over 120°F, resulting in plumber corrective action, hourly monitoring, staff in-service, and orders for system upgrades.
Inspection Report — Jun 27, 2017
Life Safety
Date: Jun 27, 2017
Visit Reason
Life Safety Code survey conducted on 2017-06-27 to determine compliance with 42 CFR Subpart 483.70(a) and NFPA 101 Life Safety Code (2012).
Findings
The facility was cited for multiple Life Safety Code deficiencies including inadequate emergency egress illumination, interior finish/insulation issues, fire alarm and smoke detector problems, sprinkler system installation and supervision failures, missing sprinkler maintenance, improperly mounted fire extinguishers, corridor door latching failures, penetrations in smoke barriers, electrical and HVAC hazards, incomplete fire plan and drills, and missing generator load tests.
Deficiencies (16)
K 0281 - Illumination of Means of Egress: emergency lighting was not provided for the full path to the public way from Building 2.
K 0331 - Interior Wall and Ceiling Finish: paper-backed insulation was installed in the Building 2 basement with the backing exposed.
K 0341 - Fire Alarm System - Installation: pull stations were mounted at an incorrect height in Buildings 1 and 2.
K 0342 - Fire Alarm System - Initiation: smoke detectors were located in the airflow stream at the nurse's station and A Hall lobby in Building 1.
K 0345 - Fire Alarm System - Testing and Maintenance: smoke detectors 1, 9, 10, 19 and 20 were not tested for sensitivity during the past two annual inspections.
K 0351 - Sprinkler System - Installation: bathrooms, closets, attic and part of the basement in Building 2 were not protected by the sprinkler system and sprinkler piping in Building 2 attic was not protected from freezing.
K 0352 - Sprinkler System - Supervisory Signals: the OS&Y valve in the vault for Building 1 was not supervised by the fire alarm system.
K 0353 - Sprinkler System - Maintenance and Testing: sprinkler heads in the kitchen, cooler and freezer in Building 1 were loaded with grease and the backflow valve had not been tested.
K 0355 - Portable Fire Extinguishers: portable fire extinguishers were mounted too high in Buildings 1 and 2.
K 0363 - Corridor - Doors: sleeping room doors A10 and C5 in Building 1 did not latch.
K 0372 - Subdivision of Building Spaces - Smoke Barrier: there were unprotected or improperly protected penetrations in corridor smoke walls and rated ceilings (storage rooms, mechanical rooms, above ceiling areas and top of rated walls) in Building 1.
K 0511 - Utilities - Gas and Electric: electrical hazards were observed including flexible cord running through the Dining Room ceiling, exposed nonmetallic wiring in the Building 2 basement, an electrical panel blocked in Building 2, use of an extension cord as permanent wiring in Building 1, and exposed wiring above a refrigerator.
K 0521 - HVAC: fuel-fired heating equipment was receiving makeup air from the attic through an opening and combustibles were stored next to fuel-fired equipment, and a combustible guard had been constructed around fuel-fired equipment in the laundry (Buildings 1 and 2).
K 0711 - Evacuation and Relocation Plan: the facility fire plan did not contain all required elements and omitted calling 911 for all alarms.
K 0712 - Fire Drills: fire drills were not properly conducted because the fire alarm was not activated during drills conducted between 9:00 p.m. and 6:00 a.m.
K 0918 - Electrical Systems - Essential Electric System Maintenance and Testing: monthly generator load test records were missing for December 2016, January 2017 and February 2017.